期刊文献+

纤维桩修复残根残冠失败13例原因分析 被引量:1

下载PDF
导出
摘要 目的探讨纤维桩修复残根残冠失败的原因,提高修复成功率。方法对2009年8月至2011年7月间经玻璃纤维桩修复残冠残根失败患者13例临床资料进行回顾性分析,总结修复失败的原因。结果 13例修复失败患者中纤维桩松动8例,主要原因为残余牙体组织过少、牙本质肩领不完整、根管腔较大,纤维桩型号不符、上前牙内倾及深覆;纤维桩脱落、桩断裂3例,主要原因为根管过细;根折2例,主要原因为根管壁薄,牙体残余少。结论纤维桩修复残根残冠失败受多种因素影响,主要表现为桩折和桩脱,临床应严格纤维桩修复适应证选择,规范操作,降低修复失败率。
作者 史莉 宜云州
出处 《中国医药指南》 2014年第12期172-173,共2页 Guide of China Medicine
  • 相关文献

参考文献4

  • 1赵海军,刘国勤,张庆福,陈骏,王晓曼.玻璃纤维增强树脂桩核在残冠残根修复中的临床应用[J].口腔颌面修复学杂志,2007,8(1):28-30. 被引量:31
  • 2冯海兰,徐军.口腔修复学[M].北京:北京大学医学出版社,2010:29.
  • 3Cormier CJ,Burns DR,Moon P.In vitro comparison of thefracture res-istance and failure mode of fiber,ceramic,andconventional post systems at various stages of restoration[J].JProsthodont,2001,10(1):26-36.
  • 4SilvaNR,Castro CG,Santos-Filho PC,et al.Influence of differentpost design and composition on strew distribution inmaxillarycentral incisor; finite elementanalysis[J].Indian J DentRes,2009,20(2):153-158.

二级参考文献9

  • 1李冰,张并生,葛学军,武秀萍.碳纤维桩核冠修复年轻恒牙冠折[J].口腔颌面修复学杂志,2005,6(3):211-212. 被引量:7
  • 2赵海军,刘国勤,季秋杰,张新海,刘海英.负压抽吸硅橡胶印模应用于铸造桩核冠修复的临床研究[J].海军医学杂志,2005,26(3):195-197. 被引量:5
  • 3Manning KE, Yu DC, Yu HC, et al. Factor to consider for predictable post and core build-ups of endodontically treatedteeth. Part Ⅰ: Basic theoretical concepts [J]. J Can Dent Assoc, 1995, 61(8):685-688
  • 4马轩祥.口腔修复学[M].5版,北京:人民卫生出版社,2004:89-96
  • 5Malquarti G, Berruet RG, Bios D. Prosthetic use of carbon fiber-reinforced epoxy resin for esthetic crowns and fixed partial dentures[J]. J Prosthet Dent, 1990, 63 (3): 251-257
  • 6Sorensen JA, Martinoft JT. Intracoronal reinforcement and coronal coverage: a study of endodontically treated teeth[J].J Prosthet Dent, 1984, 51(6):780-784
  • 7Heydecke G, Butz F, Hussein A, et al. Fracture strength after dynamic loading of endodonficaUy treated teeth restored with different post-and-core systems[J]. J Prosthet Dent, 2002, 87(4):438-445
  • 8Wataha JC, Lockwood PE, Khajotia SS, et al. Effect of pH on element release from dental casting alloys [J]. J Prosthet Dent, 1998, 80(6):691-698
  • 9Stewardson DA. No-metal post system [J]. Dent. Update,2001, 128(9): 326-336

共引文献35

同被引文献2

引证文献1

相关作者