分析了津滨轻轨车辆段小站台附近分段绝缘器"拉弧"现象的原因、采取的消除措施及效果,对新建车辆段小站台的选址、分段绝缘器的设计和安装提出了建设性意见。
The “drive stroke”of section insulator in small platform which in Jinbin light-railway's vehicles analyzed. Some soulation and effection is introduced, too. There are also some constructive suggestion selecting the location of small platform .The suggestion of designing and installing of the section insulator is section is about the provided,