期刊文献+

民用建筑室内氨污染研究进展 被引量:11

Research Progress of Indoor Ammonia Pollution in Civil Buildings
下载PDF
导出
摘要 针对民用建筑室内空气氨污染问题,从室内空气氨污染现状、污染来源、释放规律、对人体健康影响以及相关控制措施等方面综述了国内外研究进展。研究发现,我国室内空气氨污染情况较为复杂,美容美发场所氨污染较重,其他民用建筑室内空气氨污染北方比南方严重,且主要来源于建筑材料和装修材料;国外污染情况较轻;国内外对于室内空气中低浓度氨对人体健康的影响研究都不多;我国关于民用建筑室内空气氨污染控制措施的研究较多,而国外则主要集中在农牧业养殖场室内空气氨的控制;我国针对室内空气氨污染制定了一系列相关标准及规范,而除芬兰外其他发达国家鲜见相关报道。最后,针对存在的问题提出进一步开展研究的建议。 Aiming at the problem of indoor ammonia pollution in civil buildings, the research progress of current status, polluting sources, releasing rules, effects on human health and related control measures of indoor ammonia pollution at home and abroad was introduced. The results show as follows: the indoor ammonia pollution in China is complex, and the hairdressing sites are highly polluted with ammonia; in other civil constructions, the indoor ammonia pollution is mainly due to the construction and decoration materials and has regional differences, with worse pollution in northern part of the country than in southern part. The pollution abroad is less serious in foreign developed countries. The research on the effect of low-level ammonia pollution on human health is rare both at home and abroad. The domestic researches focused on indoor ammonia pollution prevention while foreign researches mainly focused on the control of indoor ammonia pollution at the field of husbandry and aquaculture. China had established a series of standards or regulations about indoor ammonia pollution while there were no related reports in other developed countries except Finland. Finally, suggestions on further researches on indoor ammonia pollution were put forward.
出处 《环境工程技术学报》 CAS 2014年第3期212-219,共8页 Journal of Environmental Engineering Technology
关键词 民用建筑 室内空气污染 civil building indoor air pollution ammonia
  • 相关文献

参考文献74

  • 1吴晓泉.混凝土结构工程氨气污染治理初探[J].混凝土,2001(1):60-61. 被引量:2
  • 2戴天有,刘德全,曾燕君,刘士励,Robert Carley,康剑石.装修房屋室内空气的污染[J].环境科学研究,2002,15(4):27-27. 被引量:56
  • 3WANNER H V. Indoor air pollution by building material [J].Environment International, 1986,12:311.
  • 4JONES A P. Indoor air quality and health [J] . AtmosphericEnvironment, 1999,33 :4535-4564.
  • 5王簇兰.劳动卫生学[M].3版.北京:北京人民出版社,1995:48-51.
  • 6邓健,许金生,樊华,袁亚莉,刘新泰,易炎启.长期接触低浓度氨工人肝功能的改变[J].中国工业医学杂志,2004,17(1):41-42. 被引量:4
  • 7SISOVIC A, SEGA K. Indoor/outdoor relationship of ammoniaconcentrations in selected office building [J]. Science of TotalEnvironment, 1987,61 (3) :73-77.
  • 8HILTUNEN K. Ammonia in indoor air in Finnish homes [M].Helsinki:City of Helsinki Environment Centre,2000.
  • 9王宝祥,杨娟.美发店空气氨污染对健康影响的调査[J].吉林预防医学,2004,7(3/4) :99-100.
  • 10封锦芳,张立深.北京市13所美发厅室内空气第:污染调査[J].卫生研究,1996,25(4):220.

二级参考文献116

共引文献350

同被引文献78

引证文献11

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部