期刊文献+

Application of a Current and Voltage Mixed Control Mode for the New Fast Control Power Supply at EAST 被引量:4

Application of a Current and Voltage Mixed Control Mode for the New Fast Control Power Supply at EAST
下载PDF
导出
摘要 A feedback control system is needed to restrain plasma vertical displacement in EAST (Experimental Advanced Superconducting Toknmak). A fast control power supply excites active feedback coils, which produces a magnetic field to control the plasma's displacement. With the development of EAST, new demands on the new fast control power supply have led to an enhanced ability of fast response and output current, as well as a new control mode. The structure of cascaded and paralleled H-bridges can meet the demand of extended capacity, and digital control can reMize current and voltage mixed control mode. The validity of the proposed scheme is confirmed by experiments. A feedback control system is needed to restrain plasma vertical displacement in EAST (Experimental Advanced Superconducting Toknmak). A fast control power supply excites active feedback coils, which produces a magnetic field to control the plasma's displacement. With the development of EAST, new demands on the new fast control power supply have led to an enhanced ability of fast response and output current, as well as a new control mode. The structure of cascaded and paralleled H-bridges can meet the demand of extended capacity, and digital control can reMize current and voltage mixed control mode. The validity of the proposed scheme is confirmed by experiments.
出处 《Plasma Science and Technology》 SCIE EI CAS CSCD 2014年第4期420-423,共4页 等离子体科学和技术(英文版)
基金 supported by ITER Program of China(973 Program)(No.2011GB109002) National Natural Science Foundation of China(No.11275056) Hefei University of Technology Doctor Research Foundation of China(No.2011HGBZ1292)
关键词 EAST plasma vertical unstable displacement fast control power supply current and voltage mixed control mode EAST, plasma, vertical unstable displacement, fast control power supply,current and voltage mixed control mode
  • 相关文献

参考文献6

  • 1Bondeson A, Liu D-H, S6dner F X, Persson M, et al. 1999, Nuclear Fusion, 39:1523.
  • 2Liu Chengyue, Chen Meixia, Wu Bin. 2009, Nuclear Pusion and Plasma Physics, 29:a01 (in Chinese).
  • 3Liu Chengyue, Chen Meixia, Song Fengquan. 2008, Journal of Hefei University of Technology (Natural Sci- ence), 31:314 (in Chinese).
  • 4Liu Lei. 2008, Simulation of Vertical Instability and Feedback Control in EAST PhD. Institute of Plasma Physics, Chinese Academy of Sciences, Hefei (in Chi- nese).
  • 5Huang Haihong, Gao Ge, Fu Peng, et al. 2008, Nuclear Fusion and Plasma Physics, 28:358 (in Chinese).
  • 6Favez J-Y, Lister J B, Miilhaupt Ph, et al. 2005, Plasma Physics and Controlled Fusion, 47:1709.

同被引文献24

引证文献4

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部