期刊文献+

Dual motion fretting wear behaviors of titanium and its alloy in artificial saliva 被引量:1

纯钛和钛合金在人工唾液中的复合微动磨损行为(英文)
下载PDF
导出
摘要 A dual motion combined by radial and tangential fretting was achieved on a modified hydraulic fretting wear test rig. The dual motion fretting tests of medical pure titanium (TA2) and Ti6Al7Nb alloy in artificial saliva were carried out under varied contact inclined angles (45° and 60°), and the maximum imposed load varied from 200 to 400 N at a constant loading speed of 6 mm/min. The effects of the cyclic vertical force and the inclined angle were investigated in detail. Dynamic analysis in combination with microscopic examinations shows that the wear scar and plastic deformation accumulation present a strong asymmetry. The Ti6Al7Nb has better wear resistance than TA2 in artificial saliva at the same test parameters, and with the increase of inclined angle and decrease of imposed load, the wear reduces accordingly. The wear mechanisms of pure titanium TA2 and Ti6Al7Nb alloy under the condition of dual motion fretting in artificial saliva are abrasive wear, oxidative wear and delamination. 在改进后的液压伺服双向微动磨损试验机上实现双向微动。在人工唾液环境中,对TA2纯钛和Ti6Al7Nb合金在6 mm/min的加载速度下以不同接触倾角(45°和60°)和不同最大外加载荷(200-400 N)条件下进行复合微动磨损实验。详细研究循环垂向力和倾斜角的影响。结合动力学分析与微观检测结果显示:磨痕和塑性变形累积呈现强烈的非对称性。在人工唾液环境中和相同实验参数下,Ti6Al7Nb合金比TA2纯钛具有更好的抗磨损性能,并随着倾斜角度的增加和外加载荷的降低,磨损相应减轻。TA2纯钛和Ti6Al7Nb合金在人工唾液环境中的复合微动磨损机制是磨粒磨损、氧化磨损和剥层。
出处 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2014年第1期100-107,共8页 中国有色金属学报(英文版)
基金 Project(81170996)supported by the National Natural Science Foundation of China
关键词 titanium alloy fretting wear dual motion fretting tangential fretting radial fretting wear mechanism 钛合金 微动磨损 双向复合微动 切向微动 径向微动 磨损机理
  • 相关文献

参考文献17

  • 1SONES A D. Complications with osseointegrated implants [J]. J Prosthet Dent, 1989, 62:581-585.
  • 2YOKOYAMA K, ICHIKAWA T, MURAKAMI H, MIYAMOTO Y, ASAOKA K. Fracture mechanisms of retrieved titanium screw thread in dental implant [J]. Biomaterials, 2002, 23: 2459-2465.
  • 3ZHU M H, CAI Z B, LI W, YU H Y, ZHOU Z R. Fretting in prosthetic devices related to the human body [J]. Tribology International, 2009, 42: 1360-1364.
  • 4YU H Y, CAI Z B, ZHOU Z R, ZHU M H. Fretting behavior of cortical bone against titanium and its alloy [J]. Wear, 2005, 259(7-12): 910-918.
  • 5GAO S S, CAI Z B, QUAN H X, ZHU M H, YU H Y. Comparison between radial and dual-motion fretting features of cortical bone [J]. Tribology International, 2010: 440-446.
  • 6YU H Y, GAO S S, CAI Z B, QUAN H X, ZHU M H. Dual-motion fretting behavior of mandibular cortical bone against pure titanium [J]. Tribology International, 2009, 42: 1365-1372.
  • 7TOMOYA G, YOSH1NOBU M, JOANNE N W, MICHAELL M. Fracture incidence in mandibular overdentures retained by one or two implants [J]. The Journal of Prosthetic Dentistry, 2010, 103: 178-181.
  • 8SIVAKUMAR B, SATENDRA K, SANKARA T S N. Fretting corrosion behaviour of Ti6A14V alloy in artificial saliva containing varying concentrations of fluoride ions [J]. Wear, 2011, 270: 317-324.
  • 9BARRY M, KENNEDY D, KEATING K, SCHAUPERL Z. Design of dynamic test equipment for the testing of dental implants [J]. Materials and Design, 2005, 26: 209-216.
  • 10JAARDA M J, RAZZOOG M E, GRATTON D G. Effect of preload torque on the ultimate tensile strength of implant prosthetic retaining screws [J]. Implant Dent, 1994, 3: 17-21.

同被引文献2

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部