期刊文献+

微波消解-原子荧光光谱法测定豆粉中总汞的不确定度评定 被引量:2

Uncertainty Evaluation of Mercury in Bean Flour with Microwave Digestion-atomic Fluorescence Spectrometry
下载PDF
导出
摘要 为了得到准确而完善的检测结果,对微波消解-原子荧光光谱法测定豆粉中总汞结果的不确定度进行了评定,结合各不确定度分量对测定方法中不确定度的主要来源进行了分析。结果表明:样品的前处理方法以及试样的重复性对获得准确测定结果尤为重要,标准曲线的配制也是重要的不确定度来源,同时需要确保仪器的稳定性,而试样定容和样品称样引入的不确定度极低,可以忽略。通过不确定度的评定,明确了测定过程中主要误差的来源,为降低检测过程中的误差提供了依据。 In order to obtain accurate and sophisticated determination results, the uncertainty was evaluated in determination results of total mercury in bean flour by microwave digestion-atomic fluorescence spectrometry. Combined with the various components of uncertainty, the main sources of uncertainty in determination method were analyzed. The results showed that repetitiveness and pretreatment method of sample were particularly important, so was preparation of standard curve, the stability of the instrument must be ensured, the uncertainty of sample volume and sample weight could be ignored for its low. Through the evaluation of uncertainty, the main source of error in determination process was explicit, the basis for reducing the error in determination process was provided.
作者 杜英秋
出处 《黑龙江农业科学》 2014年第5期106-109,124,共5页 Heilongjiang Agricultural Sciences
关键词 豆粉 微波消解 原子荧光光谱法 不确定度 bean flour microwave digestion atomic fluorescence spectrometry mercury uncertainty
  • 相关文献

参考文献6

二级参考文献95

共引文献119

同被引文献5

  • 1李其树.湿法消解-原子荧光分析法测定饮料中锡含量的不确定度评定[J].轻工科技,2011,27(12):14-17. 被引量:2
  • 2中国实验室国家认可委员会.化学分析中不确定度的评估指南[M].中国计量出版社,2002.
  • 3全国法制计量管理计量技术委员会.JJF1059.1-2012测量不确定度评定与管理[S].北京:中国质检出版社,2012:8-9.
  • 4全国流量容量计量技术委员会.JJG169-2006常用玻璃量器检定规程[s].北京:中国计量出版社,2006:6-8.
  • 5中华人民共和国卫生部.GB 5009.93-2010食品安全国家标准食品中硒的测定[S].中国标准出版社,2010:1-3.

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部