期刊文献+

3种方法表面处理后钯银合金与聚合瓷结合性能比较 被引量:1

Comparison of Pd-Ag alloy and polymerization porcelain's bonding properties after three kinds of surface treatments
下载PDF
导出
摘要 目的比较3种方法表面处理后钯银合金与聚合瓷的结合性能,研究能够有效提高钯银合金与聚合瓷结合性能的方法。方法制作18个钯银合金试件,平均分为3组,喷砂组常规表面喷砂处理,酸蚀组用质量分数4.9%氢氟酸行表面处理,硅涂层组用Rocatec-plus粉行表面处理。测定3组试件与聚合瓷的剪切粘接强度,并用扫描电镜观察3组断裂面形貌。结果喷砂组、酸蚀组、硅涂层组的剪切粘接强度分别为(11.93±1.01)MPa、(18.39±1.70)MPa、(23.75±1.11)MPa,差异有统计学意义(P<0.05)。结论 3种表面处理方法中,硅涂层方法的钯银合金与聚合瓷结合性能最好。 Objective Through comparing bonding properties of Pd-Ag alloy and polymerization porcelain after three kinds of surface treatments, to study how to effectively improve bonding properties of Pd-Ag alloy and polymerization porcelain. Methods Eighteen Pd-Ag alloy specimens were prepared and divided into three even groups. Sandblasting group used conventional surface sandblasting, acid corrosion group treated the surface with 4.9% hydrofluoric acid, silica coating group used Rocatee-plus powder for surface treatment. Then, shear bond strength of three group specimens with polymerization porcelain was measured and fi'acture surface was observed in scanning electron microscope. Results The shear bond strength were ( I 1.93 ~ 1. O1 ) MPa in sandblasting group, ( 18.39 ~ 1.70) MPa in HF acid corrosion group, ( 23.75 :t: 1.11 ) MPa in silicon coating group, the difference was statistically significant ( P 〈 O. 05 ). Conclusion Pd- Ag alloy and polymerization porcelain' s bonding properties after silicon coating was the best among three surface treat- ments.
出处 《广东牙病防治》 2014年第4期173-175,共3页 Journal of Dental Prevention and Treatment
基金 深圳市知识创新计划基础研究项目(JCYJ20130401100254192)
关键词 钯银合金 表面处理 剪切强度 合金 牙瓷料 工艺学 牙科 抗剪切强度 Pa-Ag polymerization Porcelain Surface treatment Shear strength
  • 相关文献

参考文献7

二级参考文献42

  • 1蔡伯华,秦江.Artglass玻璃瓷牙的临床应用[J].现代康复,1999,3(1):96-96. 被引量:4
  • 2钟兆伟,谢伟丽,朱兴国,马欣新,李长城.纯钛表面离子注氮后的金瓷结合观察[J].口腔颌面修复学杂志,2006,7(2):105-107. 被引量:7
  • 3庄晶,汪饶饶.口腔修复用金属析出离子的生物学效应的研究现状[J].口腔材料器械杂志,2007,16(1):40-42. 被引量:4
  • 4Grimaudo NJ. Biocompatibility of nickel and cobalt dental alloys. Gen Dent, 2001,49 (5) :498-503.
  • 5Berzins DW, Kawashima I, Graves R, et al. Electrochemical characteristics of hlgh-Pd alloys in relation to Pd-allergy. Dent Mater, 2000,16(4) :266-273.
  • 6Holland RI. Use of potentiodynamic polarization technique for corrosion testing of dental alloys. Scand J Dent Res, 1991,99( 1 ) :75-85.
  • 7Marchante-Gayon JM, Muniz CS, Garcia Alonso JI, et al. Multielemental trace analysis of biological materials using double focusing inductively coupled plasma mass spectrometry, detection. Anal Chim Acta, 1999,400:307-320.
  • 8Huang HH. Effect of fluoride and albumin concentration on the corrosion behavior of Ti-6Al-4V alloy. Biomaterials, 2003,24 (2) : 275- 282.
  • 9Alkhiary YM,Morgano SM,Giordano RA.Effects of acid hydrolysis and mechanical polishing on surface residual stresses of low-fusing dental ceramics[J].J Prosthet Dent,2003,90(2):133-142.
  • 10Burke FJ,Fleming G J,Nathanson D,et al.Are adhesive technologies needed to support ceramics? An assessment of the current evidence[J].J Adhes Dent,2002,4(1):7-22.