期刊文献+

能量回馈式负载装置高精度加载策略及应用研究 被引量:4

High precision load strategy and application research for energy feedback load device
下载PDF
导出
摘要 相对于传统加载装置,由变频器及伺服电机所组成的能量回馈式负载单元具有动态响应快、测试节能等优点,已在测试领域得到广泛应用。但是,受负载电机与被试电机机械联接影响,该负载单元加载精度并不理想。以一套电动机能效测试系统为例,建立了该负载单元的抽象简化模型,分析了影响加载精度的原因;提出了两种高精度加载策略,并给出软件通讯方案设计。实测表明,采用比例积分控制及模糊控制策略后,该负载单元的加载精度可由7.0%提升至变频器驱动精度1.0%,能量回馈率高达93%,节能效果显著。 Comparing with traditional load devices, the energy-feedback load unit that servo motor driven by converter owns a variety of advantages like fast dynamic response and energy-saving test, etc. , which is widely used in the tes- ting field recently. However, load precision is not so ideal because of mechanical connection between test motor and servo motor. Taking a motor efficiency test system for example, the paper establishes the simplified model of load unit and analyzed the reasons and aspects of low-precision load in details. Moreover, two high-precision load strategies and design of software communication scheme are presented. Field test indicates that after adopting the proportion integrator (PI) or fuzzy control strategy, load precision can increase effectively from 7.0 % to 1.0 % , and energy saving rate ran up to 93 % maximally and energy conservation effect is remarkable.
出处 《华北电力大学学报(自然科学版)》 CAS 北大核心 2014年第2期15-19,共5页 Journal of North China Electric Power University:Natural Science Edition
基金 国家自然科学基金资助项目(51307050) 中央高校基本科研业务费项目
关键词 高精度加载 能量回馈 变频器 伺服电机 high-precision load energy feedback converter servo motor
  • 相关文献

参考文献12

二级参考文献42

共引文献76

同被引文献49

  • 1齐维贵,朱学莉,张延丽.抽油机节能的模糊神经网络控制研究[J].中国电机工程学报,2004,24(6):137-140. 被引量:27
  • 2闫华光,范滢,段小华,宗建华.基于电能回馈技术的电机智能测试系统[J].电机与控制应用,2007,34(2):52-55. 被引量:9
  • 3叶双,郭耀华.变频器在电机测试平台的应用[J].唐山学院学报,2007,20(6):43-44. 被引量:2
  • 4Braun D H,Gilmore T P,Maslowski W A.Regenerative Converter for PWM AC Drivers[C].USA:IEEE,1991,1:862-868.
  • 5Wang B,Zhao H S,Lian S J.Study on precision selection of instrument transformer and its calibration for automatic test system[J].Trans Tech Publications Ltd,2013,333-335(2):2461-2464.
  • 6Gibbs S G, Miller D L. Inferring power consumption and electrical performance from motor speed in oil-well pumping units[J]. IEEE Transactions on Industry Applications, 1997, 33(1): 187-193.
  • 7API RP 11L. Design calculation of Sucker rod pumping system[S]. Washington. American Petroleum Institute, 1967.
  • 8Luo Yingli, Cui Xueshen. A multifunction energy saving device with a novel power-off control strategy for beam pumping motors[J]. IEEE Transactions on Industry Applications, 2011, 47(4). 1605-1611.
  • 9Dong Shimin, Cui Yang. The dynamic simulation model and comprehensive simulation algorithm of the beam pumping system[C]//International Conference on Mechanical and Automation Engineering. Jiujiang, China, 2013.
  • 10Aydogmus O, Sunter S. Four-quadrant operation of PMSM drive fed by a matrix converter[C]//IEEE International Conference on AC EMP. Istanbul: IEEE, 2011: 436-439.

引证文献4

二级引证文献41

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部