期刊文献+

微孔板法测定功能性饮料中的维生素B_(12)

Determination of Vitamin B_(12) in Energy Drinks by Microplate Method
下载PDF
导出
摘要 通过样品处理比较试验、色素影响评价、回收率试验和重复性试验,得到了微孔板法测定功能性饮料中维生素B12的有效方法。经测定,该方法测定限可达到0.005μg/L,1.0、2.0、20.0μg/L三个梯度水平的加标回收率为94.4%~101.8%,实际样品测定中相对标准偏差为0.35%~4.34%(n=6),灵敏度和重复性很高,可用于测定功能性饮料中微量的维生素B12。 The optimal microplate method for determination of vitamin B 12 in energy drinks was confirmed through the tests on comparison of sample treatment methods , pigment impact assessment , recovery and repeat-ability.The detection limit of the method could reach 0.005μg/L.The recovery rate was 94.4%~101.8%at 1.0、2.0、20.0 μg/L of vitamin B12 gradient; the relative standard deviation in actual test was 0.35%~4.34%(n=6).For the high sensitivity and reproducibility , this method could be used for the determination of light vitamin B12 in energy drinks.
出处 《山东农业科学》 2014年第4期110-113,共4页 Shandong Agricultural Sciences
关键词 微孔板法 测定 功能性饮料 维生素B12 VITAMIN B12 Microplate method Determination Energy drinks
  • 相关文献

参考文献18

  • 1中华人民共和国国家质量监督检验检疫总局.GB10789-2007饮料通则[s].北京:中国标准出版社,2007.
  • 2罗魏,刘学文,王永欢,胡海宾.功能性饮料的发展现状及展望[J].食品工业科技,2011,32(2):418-421. 被引量:27
  • 3文剑.功能饮料市场现状及未来发展方向[J].食品与发酵工业,2007,33(4):101-106. 被引量:11
  • 4叶芳青,孙袁,蒋小亚,刘建西,张志萍,张萍.孕妇血浆叶酸、维生素B_(12)和同型半胱氨酸水平测定及临床意义[J].中国妇幼保健,2006,21(16):2230-2232. 被引量:31
  • 5崔明,杨大进,鲁杰,王竹天.V_B_(12)检测技术研究进展[J].食品与发酵工业,2011,37(4):166-171. 被引量:8
  • 6Sharma R, Rajput Y S, Dogra G, et al. Estimation of vitamin B12 by ELISA and its status in milk [ J ]. Milchwissenschaft, 2007, 62(2) :127 - 130.
  • 7Campos- Gimenez Esther, Fontannaz Patric, Trisconi Marie- Jose, et al. Determitnation of vitamin B12 in food products by liq- uid chromatography/UV detection with immunoaffinity extraction : single - laboratory validation [ J ]. Journal of AOAC International,2008,91 (4) :786 - 793.
  • 8Marley E C, MacKay E, Young G. Characterization of vitamin B12 immunoaffinity columns and method development for determination of vitamin B12 in a range of foods, juices and pharma- ceutical products using immunoaffinity clean - up and high performance liquid chromatography with UV detection [ J ]. Food Additives & Contaminants, 2009, 26 ( 3 ) :282 - 288.
  • 9Kumar S S, Chouhan R S, Thakur M S. Enhancement of chemiluminescence for vitamin B12 analysis [J]. Analytical Biochemistry, 2009, 388(2):312-316.
  • 10Li H B, Chen F. Determination of vitamin B12 in pharmaceutical preparation by a highly sensitive fluorimetric method [ J ]. Fresenius Journal of Analytical Chemistry, 2000, 368 (8):836 - 838.

二级参考文献54

共引文献113