期刊文献+

1000MW超超临界机组TSI系统调试及改进

Debugging and improvement of TSI system of 1 000 MW ultra supercritical unit
下载PDF
导出
摘要 以广东惠州平海发电厂有限公司1000 MW超超临界机组为例,对汽轮机安全监视保护(TSI)系统进行了介绍,在历次检修经验的基础上,提出了提高系统稳定性和可靠性的改进方案。根据方案对涡流探头的间隙进行修正,并对数据处理模件进行合理组态,确保系统数据测量以及与第三方系统数据通信的准确性,保证了系统运行的稳定性。 Taking the 1000 MW ultra supercritical unit of Guangdong Huizhou Pinghai Power Plant Company Limited as example,the turbine supervisory instrument system( TSI) was introduced. Based on the previous maintenance experiences, a scheme to improve the stability and reliability of the system was proposed. According to the scheme,the gap of the eddy current probe was amended,and the data processing modules were configured rationally. The measures ensure the accuracy of the system data measurement,the correctness of the data communication with third part and the stability of system operation.
作者 陈睿霖
出处 《华电技术》 CAS 2014年第3期34-36,80,共3页 HUADIAN TECHNOLOGY
关键词 超超临界机组 汽轮机 安全监视保护系统 可靠性 改进 ultra supercritical unit steam turbine turbine supervisory instrument system(TSI) reliability improvement
  • 相关文献

参考文献4

二级参考文献3

  • 1施维新.汽轮发电机组振动及事故[M].北京:中国电力出版社,1998..
  • 2叶绍义.1000MW超超临界机组汽轮机振动原因分析及解决对策[C]//600/1000MW超超临界机组技术交流2009年年会论文集.上海:中国动力工程学会,2009.
  • 3王新宇,贾金祥,边广平,李国宝,刘永厚,史建良.200MW机组首次启动振动大的原因分析和处理[J].内蒙古电力技术,2002,20(3):29-31. 被引量:1

共引文献96