期刊文献+

人体与手机不同距离下比吸收率的研究

Research of Specific Absorption Rate under the Condition of Different Distances between Human Body and Cell Phone
下载PDF
导出
摘要 参照EN 62209-1、OET 65C的测量方法及相关要求,基于瑞士SPEAG公司生产的DASY 5测试系统,对6个品牌的手机进行了比吸收率测试。研究了手机分别工作在GSM和WCDMA两种模式下,与人体不同距离时人体对其电磁辐射比吸收率的变化。结果表明,OET 65C测试的SAR值要比EN 62209-1测试的SAR值大,且手机对身体部位的辐射更应引起重视。 According to the measurement methods and requirements of EN 62209-1 and OET 65C, based on DASY 5 test system, the specific absorption rate (SAR) for six brands of cell phones were tested. The change of SAR value was researched when mobile phone worked in GSM and WCDMA modes respectively with different distances from the human body model. Test results showed that the SAR values tested by OET 65 C were bigger than EN 62209-1, and the radiation on body regions should be more concerned.
作者 才辉 钟华彧
出处 《安全与电磁兼容》 2014年第2期35-39,共5页 Safety & EMC
关键词 手机辐射 比吸收率 测试系统 cell phone radiation specific absorption rate test system
  • 相关文献

参考文献3

  • 1EN 62209-1:2006 Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models, instrumentation, and procedures - Part 1: Procedure to determine the specific absorption rate (SAR) for hand-held devices used in close proximity to the ear(frequency range of 300 MHz to 3 GHz)[S]. 2006.
  • 2信息产业部电信研究院.YD/T1644.1-2007手持和身体佩戴使用的无线通信设备对人体的电磁照射-人体模型、仪器和规程第1部分:靠近耳边使用的手持式无线通信设备的SAR评估规程(频率范围300MHz-3GHz)[S].北京:中国标准出版社,2007.
  • 3FCC Bulletin OET-65C:2001 Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields[S]. 2001.

共引文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部