期刊文献+

飞来峡水电厂机组导叶开度异常波动原因分析

Analysis of Abnormal Opening Fluctuation of Turbine Guide Vanes in Feilaixia Hydropower Station
下载PDF
导出
摘要 主要分析了飞来峡电厂4号机组在并网运行时因导叶位置反馈传感器故障引起导叶开度异常波动的原因,阐述了故障分析、原因查找过程及改进措施。 Abnormal opening fluctuation of turbine guide vanes was observed during the operation in grid of the No .4 generator unit in Feilaixia hydropower station .And it is found that the fluctuation was caused by the failure of feedback sensor for guide vane positions .The procedure of failure analysis is introduced and improvement measures are proposed .
作者 黄秀丽
出处 《水电与新能源》 2014年第4期65-67,共3页 Hydropower and New Energy
关键词 飞来峡水电厂 导叶传感器 故障 对策 Feilaixia hydropower station guide vane sensor fault improvement measures