摘要
目的探讨改进一次性输液器排气管的位置对静脉输液过程的影响。方法在静脉输液操作中,将排气管的位置从瓶口调整到瓶子底部,从输液的安全性、平稳性、可控性以及微粒数量的改变进行比较。结果改进后输液滴速平稳,可控范围增加,同时减少了输液污染。结论改进后的方法可提高输液的安全性和有效性。
Objective To investigate the impact of improving the position of air vent tube disposable infusion on the venous transfusion .Methods Changing the position of air vent tube from the opening to bottom of the bottle during the venous transfusion and comparing with the traditional infusion from safety ,stationarity ,controllability of drop speed and changes of microparticle quantity .Results The drop speed of infusion get more stationary and controllable ,and the infusion pollution reduced at the same time after improvement of the position of air vent tube .Conclusion The improvment measures could enhance the safety and effectiveness of infusion .
出处
《吉林医药学院学报》
2014年第2期97-100,共4页
Journal of Jilin Medical University