摘要
近年来,350 MW超临界墙式切圆锅炉得到逐步推广,该炉型燃烧工况稳定,经济性较好,但是不少锅炉存在比较严重的水冷壁超温问题。基于大连开发区热电厂350 MW超临界墙式切圆锅炉水冷壁超温问题及调整解决措施,提出解决该问题的主要应对思路,可供出现同类问题参考。
In recent years, 350 WM supercritical boilers have much marketing promotion. This kind of boilers has steady firing system and is economic, but overheat problem exists in many of them. According to the measures to solve the overheat of 350 MW supercritical boilers of Dalian development zone, the main ways to solve the problem is carried out to provide reference for the same kind of problems.
出处
《能源与节能》
2014年第4期154-155,181,共3页
Energy and Energy Conservation
关键词
超临界锅炉
墙式切圆
水冷壁超温
supercritical boiler
wall-arrangement tangential firing system
overheat of water cooled wall