期刊文献+

透镜组耦合793nm LD抽运掺Tm^(3+)光纤激光器

Tm^(3+)-doped fiber lasers pumped by double lens coupling 793nm LD
下载PDF
导出
摘要 为了实现2μm激光高效输出,采用793nm激光二极管端面抽运掺Tm3+光纤激光器的方法设计了抽运光耦合系统,分析了掺Tm3+光纤激光器的交叉弛豫效应及热效应,并进行了相关的实验研究。结果表明,获得耦合系统的耦合效率为84%;当入纤抽运光功率为70W时,获得34W激光输出,斜率效率为59%,中心波长为2001.2nm,光束质量M2≤1.2。该研究结果对掺Tm3+光纤激光器的设计具有指导意义。 To achieve 2μm laser output, 793nm LD face-pumping Tm3+-doped fiber laser was adopted .Double lens coupling system was designed .Cross relaxation of Tm^3+-doped fiber laser and thermal effect were analyzed , and then the related experiments were carried out .The results show that coupling efficiency of coupling system is 84%.When the pump power is 70W, the output power is 34W with slop efficiency of 59%, central wavelength of 2001.2nm and M2 of less than 1.2.The results are helpful to design Tm^3+-doped fiber lasers.
出处 《激光技术》 CAS CSCD 北大核心 2014年第3期347-351,共5页 Laser Technology
关键词 激光器 掺Tm^3+光纤激光器 半导体激光器 透镜组耦合系统 热效应 lasers Tm^3+-doped fiber laser laser diode double lens coupling system thermal effect