期刊文献+

某核电站一期工程循环水泵进水流道模型试验探讨 被引量:2

Investigation on the Circulating Water Pump Intake Pit Model Test for Certain Nuclear Power Plant Phase One Project
下载PDF
导出
摘要 循环水泵进水流道的合理设计是核电站循环水泵和循环水系统安全经济运行的前提和重要保证。依据重力相似准则,对某滨海核电一期工程按照1∶30相似比尺设计了循环水泵进水流道试验模型,进行了流道流量分配、自由表面涡和水中涡等试验。根据试验结果确定了整流措施和消涡装置。研究结果对工程建设具有实际意义,为后续循环水泵进水流道设计奠定了良好基础。 As an indispensable precondition, reasonable design of circulating water pump (CWP) intake pit plays a vital role ensuring the secure and ecomomic operation of CWP and cireulating water system in nuclear power plants (NPP). Aceording to Froude similarity criteria, a test model with the scale ratio of 1:30 is designed and used in flow distribution test, free surface w)rtex test and submerged vortex tesi for a certain coastal NPP phase one project. The flow distribution countermeasures and anti-vortex device are determined based on the model test results, which is .f great practical significance for the projeet construction such that solid foundations can be laid for the subsequent CWP intake pit design.
作者 王保田
出处 《中国电力》 CSCD 北大核心 2014年第5期113-117,135,共6页 Electric Power
关键词 循环水泵 进水流道 模型试验 消涡装置 核电站 circulating water pump intake pit model test anti-vortex device nuclear power plant
  • 相关文献

参考文献5

  • 1徐辉,段志强,于永海.泵站有压前池流态改善措施的研究[J].排灌机械,2003,21(4):13-16. 被引量:11
  • 2熊保锋.泵站吸水室水流运动特性研究现状及展单[C]//中国水利学会第4届青年科技论坛论文集.2008.
  • 3赵建均,吴修峰.福州江阴电厂2×600MW机组新建工程循环水系统引水流道水力特性研究--引水隧道流体及循环水泵房流道物理模型试验研究报告[R].南京:南京水利科学研究院水文水资源与水利工程科学国家重点实验室,2004.
  • 4周龙才,刘士和,丘传忻.泵站正向进水前池流态的数值模拟[J].排灌机械,2004,22(1):23-27. 被引量:20
  • 5GB50256--2010泵站设计规范[S].

二级参考文献7

共引文献25

同被引文献5

引证文献2

二级引证文献3