期刊文献+

苯胺冷凝器换热管泄露失效原因分析及对策

Analysis on Leakage Causes of Aniline Condenser Heat Exchanger Tube and Countermeasures
下载PDF
导出
摘要 针对苯化工装置冷凝器换热管早期失效的问题展开讨论,提出造成腐蚀穿孔的几种原因,阐述造成腐蚀的原理。结合实际,提出改变结构形状,进行防腐处理,改善循环水质等措施,避免泄漏的发生。 Focusing on the problem of the failure at early period of condenser heat exchanger tube of benzene chemical plant installations, puts forward several causes of corrosion perforation, and expounds the theory of corrosion. Integrating theory with practice puts forward countermeasures, such as changing the structure and shape, using preservative treatment, improving recycled-water, etc. so as to try to avoid leakage.
出处 《中国特种设备安全》 2014年第5期37-40,共4页 China Special Equipment Safety
关键词 垢下腐蚀 穿孔 循环水 Corrosion scales Puncture Circulating water
  • 相关文献

参考文献3

  • 1倪挺.电梯滑动导靴系统的减摩研究及应用[M],上海:上海交通大学出版社,2010.
  • 2甘立慧.UHMWPE/CSW复合材料摩擦学性能研究[M].郑州:河南科技大学,2010.
  • 3Gina B.Vertical Transportation in Tall Buildings[J] Elevator World.2003(5).