期刊文献+

基于分布式光纤测温技术的灌注桩完整性检测 被引量:8

Bored Pile Integrity Detection Based on Optical Fiber Temperature Measurement Technology
下载PDF
导出
摘要 阐述分布式光纤测温技术的基本原理,分析灌注桩在水化热过程中桩身温度分布与其完整性的关系,提出基于分布式光纤测温技术的灌注桩完整性检测方法。开展现场试验,采用一套可行的光纤铺设方案,对测得数据进行修匀处理,得出试桩浇注完毕后的5组桩身温度分布曲线。试验结果表明:桩顶至35m段桩身完整性较好,35m至桩底段桩身存在不同程度的离析,但5次测量的桩身温度分布曲线变化趋势一致,整体温度突变不大,整个桩身没有严重的缺陷。 The basic principle of distributed optical fiber temperature measurement technology was described in the paper.A new integrity detection method was proposed based on the relationship between the integrity and bored pile temperature distribution in the course of hydration.A field test was carried out,using a set of feasible optical fiber laying scheme.Five groups of pile temperature distribution curves were obtained after pouring with the smoothing of measured data.Test results show that the integrity of pile top to 35msection is good,and 35mto pile bottom section of the pile body have different degrees of segregation,but five curve trend of pile body temperature distribution is consistent.The overall sudden temperature change is not big,and the whole pile has no serious defects.
出处 《湖北工业大学学报》 2014年第2期19-22,共4页 Journal of Hubei University of Technology
基金 湖北工业大学高层次人才项目(BSQD12054)
关键词 光纤测温技术 灌注桩 完整性检测 温度 optical fiber temperature measurement technology bored pile integrity detection temperature
  • 相关文献

参考文献4

二级参考文献22

  • 1崔何亮,施斌,徐洪钟,张丹,丁勇.BOTDR光纤温度监测技术在土木工程中的应用研究[J].防灾减灾工程学报,2004,24(3):252-256. 被引量:26
  • 2蒋小珍,雷明堂,陈渊,葛捷.岩溶塌陷的光纤传感监测试验研究[J].水文地质工程地质,2006,33(6):75-79. 被引量:33
  • 3Measures R M, Alavie T, Maakant R et al. Bragg grating fiber optic sensing for bridge and other structure. Second European Conference on Smart Structures and Materials, Glagow, Scotland, 12-14, October, 1994d, SPIE, 1994D:162- 167.
  • 4Gusmeroli V, Martinelli M, Barberis A. Thermal expansion messurements of a concrete structure by embedded fiberoptic an effective example of simuhaeous strail-temperature detection, Second European Conference on Smart Structures and Materials. Giagow, Scotland, 12-14, October, 1994d, SPIE, 1994.D: 220-223.
  • 5M. Aufleger, Th. Strobl, J. Dornstadter. Fibre Optic Temperature Measurements for Dam Monitoring E C ]. International Conference on Health Monitoring of Civil Infrastructure Systems, 24- 26, October, 1994, Chongqing University Press, 121 - 128.
  • 6JGJ106-2003,建筑基桩检测技术规范[S].北京:中国建筑工业出版社,2003.
  • 7小島謙一,伊籐裕昌,村山修,等.土構造物の計測管理に用ぃる光ファィバ-センサ-の基本特性[J].土木学会输文集,2003(750/Ⅲ-65):51-67.
  • 8日下部祐基,三浦均也,池田憲二,等.光ファィバにょる杭のひずみ測定法に関する研究[J].北海道開発土木研究月報,2004(613):45-56.
  • 9肖衡林,蔡德所,何俊.基于分布式光纤传感技术的岩土体导热系数测定方法[J].岩石力学与工程学报,2009,28(4):819-826. 被引量:26
  • 10盛谦.混凝土导热系数试验研究[J].大众科技,2009,11(8):78-80. 被引量:5