摘要 针对层式通风这一新型空调通风方式,以某一典型的空调办公室为研究对象,对不同的送风温差下办公室冬季室内环境的温度场、速度场进行了探索性实验测量。结果表明在满足规范规定的送风温差的前提下,大温差送风可以提高人体活动区的温度,降低人体活动区的风速,热舒适性更高。实验研究工作为层式通风在其他相同或类似房间气流组织的设计提供参考。 In view of the new ventilation type under stratum ventilation, this paper chooses a typical office as the research object, through measuring the temperature field and velocity field of the winter office environmental, we can obtain the results that large supply air temperature difference can improve the temperature and reduce the wind speed of the human activity areas, under the premise of meeting the specification of supply air temperature difference. The experimental research work provides reference for the design of ventilation in the same or similar room air-flow.
作者 周静 李异
出处 《制冷与空调(四川)》 2014年第2期237-240,共4页 Refrigeration and Air Conditioning
关键词 层式通风 气流组织 送风速度 热舒适性 Stratum ventilation air-flow air-supply velocity thermal comfort
  • 相关文献

参考文献7

  • 1ANSI/ASHRAE Standard55-2010, Thermal Environmental Conditions for Human Occupancy[S]. Atlanta: American Society of Heating, Refrigerating, and Airconditioning Engineers, Inc, 2010.
  • 2林章,周天泰,曾志宽.层式通风——高温空调下的出路[J].化工学报,2008,59(S2):235-241. 被引量:19
  • 3L Tian, Z Lin, Q W Wang, et al. Numerical investigation of indoor aerosol particle dispersionunder stratum ventilation and under displacementventilation[J]. Indoor and Built Environment, 2009,18(4):360-375.
  • 4ML Fong, Z Lin, KF Fong, et al. Evaluation of thermal comfort conditions in a classroom with three ventilation methods[J]. Indoor Air, 2011,21 (3):231-239.
  • 5颜晓光,敬成君,李冰.基于ADPI的房间空调器气流组织性能评价[J].制冷与空调(四川),2013,27(3):292-296. 被引量:6
  • 6GROSSMAN S, HART O. The Costs and Benefits of Ownership: A Theory of Vertical and Lateral Integration[J]. Journal of Political Economy, 1986,94(4): 691-719.
  • 7H ART O. Firms, Contracts, and Financial Structure[M]. Oxford:Oxford University Press, 1995.

二级参考文献33

  • 1王伟晗,黄志甲,许强生.不同气流组织形式下空气龄的实验研究[J].建筑热能通风空调,2006,25(2):79-82. 被引量:16
  • 2ASHRAE, Ventilation for Acceptable Indoor Air Quality (ASHRAE standard 62)[s]. Atlanta: American Society of Heating Refrigeration and Air-conditioning Engineers,1989.
  • 3Hui Zhang,Edward Arens,Sahar Abbaszadeh Fard,Charlie Huizenga,Gwelen Paliaga,Gail Brager,Leah Zagreus.Air movement preferences observed in office buildings[J]. International Journal of Biometeorology . 2007 (5)
  • 4Ministry of the Environment(MoE),Cabinet of Japan.“National Campaign to Fight Global Warming”. http://www.env.go.jp/en/press/2005/ 0428b.html . 2005
  • 5Tanabe S,Kimura K.Thermal comfort requirements under hot and humid conditions. Proceedings of the First ASHRAE Far East Conference on Air Conditioning in Hot Climates . 1989
  • 6Mayer E.New measurements of the convective heat transfer coefficients:influences of turbulence,mean air velocity and geometry of human body. Proceedings of Roomvent 1992 . 1992
  • 7Arens E.Assessment of indoor environments. Proceedings of Roomvent 2007.Keynote-lectures . 2007
  • 8Nicol F.Building research and the sustainability of the built environment in the tropics. Energy and Build . 2004
  • 9Zhao R,Sun S,Ding R.Energy and environment of residential buildings in China. Energy and Build . 2004
  • 10Li L.The improvement of summer thermal environment of ventilated-room of Xiamen in China. Proceedings of the 10 th International Conference on Indoor Air Quality and Climate . 2005

共引文献23

同被引文献16

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部