摘要
采用自动固相萃取-气相色谱/质谱技术,建立了地表水中痕量多环芳烃和有机氯农药的检测方法。调节水样pH〈2,加入1%甲醇,使用C18固相萃取柱富集,3mL丙酮+3mL二氯甲烷洗脱后浓缩定容。采用气相色谱/质谱联用的全扫描模式进行分析,选择特征离子定量,方法检出限为0.026-8.772ng/L。加标水平为0.1μg/L时,样品加标回收率在74.8%~109%之间,RSD为0.01%~14.5%。该方法自动化程度高、快速、准确、重复性好,能满足地表水体中持久性有机污染物分析的要求。
To determine trace amount of PAHs and OCPs in surface water a method was developed using gas chromatography/mass spectrometry with automatic solid-phase extraction. The steps elucidated in this paper were to adjust pH of the water sample to pH〈2, and add 1% methanol, then enrich the sample by C18 extraction cartridge; thereafter, PAHs and OCPs absorbed in the cartridge was eluted by 3 mL acetone plus 3 mL dichloromethane; the sample being concentrated, analysis was conducted by gas chromatography/mass spectrometry using the all-scan mode, and selective ion mass was used in quantitative measurement. Results of the experiment were limits of detection ranged from 0.026 to 8.772 ng/L; when average spiked recoveries for the fishery products at the spiked level attained 0.1 μg/L, ranging from 74.8% to 109%, RSD ranged from 0.01% to 14.5%. It was concluded that the method thus set up was rapid, accurate, sensitive and reliable, and could meet the requirement for analyzing persistent organic pollutants in surface water.
出处
《环境科学与技术》
CAS
CSCD
北大核心
2014年第5期102-106,共5页
Environmental Science & Technology
基金
广东省地质调查项目(1212010511216)
关键词
多环芳烃
有机氯农药
自动固相萃取
气相色谱
质谱
地表水
polynuclear aromatic hydrocarbons(PAHs)
organo-chlorine pesticides(OCPs)
automatic solid-phase extraction
gas chromatography/mass spectrometry
surface water