摘要 堆叠式高分子材料椎体扩张器前端的高分子管在工作状态下受轴向压力堆叠成"高分子团"以扩张塌陷椎体,高分子团的形状和尺寸直接影响椎体后凸成形手术的质量和效果。因此研究高分子管管壁切缝尺寸及分布与由其堆叠而成的高分子团尺寸、形状之间的关系,是椎体扩张器研发的关键问题之一。通过建立数学模型,推演出手术要求的高分子团的规格与高分子管管壁上切缝的尺寸及分布的规律,得出数学计算公式,并举例验证了切缝尺寸计算公式和分布规律的正确性,从而提高椎体扩张器的工作可靠性和效果可预测性。 The research of kerf size and distribution of the bone expander's polymer pipe, which is used to help determine the design parameters of polymer pipe, is the key technology of plastic tube bone expander research. The mathematical model is established to find the law of the bone expanders polymer pipe kerf size and distributing. This method improves the reliability of the polymer pipe design scheme and working effect of predictability.
作者 金志刚
出处 《机械》 2014年第4期15-17,26,共4页 Machinery
基金 2013年中山市科技计划项目<堆叠式高分子材料椎体扩张器的研制及产业化>(2013A3FC0341)
关键词 椎体扩张器 高分子管 褶皱 bone expander polymer pipe fold
  • 相关文献

参考文献3

二级参考文献22

  • 1郑召民,邝冠明,李佛保,卢振和,梁德,陈文贵,肖立军.Sky骨扩张器在经皮椎体后凸成形术中的临床应用[J].中国脊柱脊髓杂志,2005,15(3):166-169. 被引量:35
  • 2Fourney DR, Schomer DF, Nader R, et al. Percutaneous vertebroplasty and kyphoplasty for painful vertebral body fractures in cancer patients [J]. J Neurosurg, 2003, 98 (1) :21-30.
  • 3Theodorou DJ, Theodorou SJ, Duncan TD, et al. Percutaneous balloon kyphoplasty for the correction of spinal deformity in painful vertebral body compression fractures [J]. Clin Imaging, 2002, 26(1 ) : 1-5.
  • 4Liu JT, Liao WJ, Tan WC, et al. Balloon kyphoplasty versus vertebroplasty for treatment of osteoporotic vertebral compression fracture : a prospective, comparative, and randomized clinical study [J]. Osteoporos Int, 2010, 21 (2) :359-364.
  • 5Kasperk HC, Hillmeier J, Noldge G,et al. Treatment of painful vertebral fractures by kyphoplasty in patients with primary osteoporosis: a prospective nonrandomized controlled study [J]. J Bone Mineral Res, 2005, 20 (4): 604-612.
  • 6Hardouin P, Fayada P, Leclet H,et al. Kyphoplasty [J]. Joint Bone Spine, 2002, 69(3) :256-261.
  • 7Foo LS, Yeo W, Fook S,et al. Results, experience and technical points learnt with use of the SKy Bone Expander kyphoplasty system for osteoporotie vertebral compression fractures : a prospective study of 40 patients with a minimum of 12 months of follow-up [J]. Eur Spine J, 2007, 16(11):1944-1950.
  • 8Galibert P, Deramond H, Rosat P, et al. Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty [J]. Neurochirurgie,1987, 33(2) : 166-168.
  • 9Hollingworth W, Jarvik JG. Evidence on the effectiveness and cost-effectiveness of vertebroplasty: a review of policy makers' responses [J]. Acad Radiol,2006,13 (5):550- 555.
  • 10Garfin SR, Yuan HA, Reiley MA. New technologies in spine: kyphoplasty and vertebroplasty for the treatment of painful osteoporotic compression fractures [J]. Spine, 2001,26(14) : 1511-1515.

共引文献31

同被引文献1

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部