期刊文献+

无苯溶剂-等量电位滴定法测定油品中碱性氮化物含量

Determination of base nitrogen content in oils by equal-increment-potentiometric titration with benzene-free solvent
下载PDF
导出
摘要 以乙酸-丙酸混合物(二者体积比为1∶3)为高氯酸滴定剂溶剂,石油醚-乙酸混合物(二者体积比为1∶1)为样品溶剂,同时采用两步溶解方式,运用等量电位滴定法测定油品中的碱性氮化物含量.结果表明,新溶剂配方的0.02 mol/L高氯酸滴定液,在凝固点下降同时,标定终点清晰,稳定性良好;以原油为基体,蜡油为标准物,通过回收率实验进行了方法准确度测定,回收率为98.6%~103.0%,表明该方法的准确度高;无论是浅色油品还是深色油品,最大相对标准偏差为1.83%,实际样品的5次测定结果的最大差值仅为允许差值(SH/T 0162标准规定的重复性指标)的25%~100%. The content of basic nitrogen in oil was determined with the mixture of acetic acid and pro- pionic acid(volume ratio 1:3) as the solvent of per- chloric acid titrant, the mixture of petroleum ether and acetic acid ( volume ratio 1:1 ) as the solvent of sample oil by the equal- increment- potentiometric titration method with two - step solution mode. The results showed that the terminal point was clearly demarcated, its stability was better, the condensation point of titrant was decreased when 0.02 mol/L per- chloric acid solution in new mixed solvent was used. The recovery rate of addition standard was in therange of 98.6% -103.0% with crude oil as matrix and wax oil as standard substance. No matter wheth- er the sample oil was light or dark, the relative standard deviation was 1.83% ,indicating this meth- od had high accuracy. The maximum differences of 5 repeated determination results of the actual sam- pies were only 25% - 100% of the tolerance in SH/ T 0162 standard.
作者 程泉 陆克平
出处 《石化技术与应用》 CAS 2014年第3期255-258,共4页 Petrochemical Technology & Application
关键词 电位滴定 石油醚 丙酸 无苯溶剂 碱性氮化物含量 potentiometric titration petroleumether propionic acid benzene - free solvent basenitrogen content
  • 相关文献

参考文献7

二级参考文献24

共引文献44

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部