以阳光城国际广场空调防排烟设计为研究对象,介绍了空调冷热负荷及冷热源的选择,对空调风系统与水系统的设计策略进行了探讨,并分析了防排烟的设计方式,得到了一些新的设计理念,以供参考。
Taking internal square air-conditioning smoke design of Yangguang city as the research target, the paper introduces the hot and cool load and hot-cold source selection of air-conditioning, explores the design strategies of air-conditioning wind system and water system, and analyzes the smoke control design methods, and finally draws new design concepts, with a view to provide some guidance.
出处
《山西建筑》
2014年第15期139-140,共2页
Shanxi Architecture
关键词
空调
防排烟
设计
酒店
air-conditioning, smoke control, design, hotel