期刊文献+

一种可调整动作时间的模拟断路器 被引量:1

Simulated Circuit Breaker with Adjustable Operation Time
下载PDF
导出
摘要 针对数字式继电保护装置测试中的模拟断路器动作时间不可控,进而影响到保护装置整组动作及其它功能的测试的问题,设计一种基于msp430单片机芯片并辅加简单外围电路所构成的模拟断路器。该装置可通过软件调整模拟断路器固有合闸与跳闸时间,并可方便地接收数字式继电保护装置发出的保护动作信号,显示断路器各相的状态。经测试,该模拟断路器可有效提高继电保护及安全自动装置的测试质量。 In the test of digital relay protection device, the operation time of simulated circuit breaker is not controllable, it will affect the whole group action test for digital relay protection device and other functional test. A software written by MSP430 microcontroller is designed by aided simple peripheral circuit to adjust the closing and tripping times of simulated circuit breaker. The simulated circuit breaker can receive the action signals of digital relay protection equipment, and display the state of circuit breaker. The simulated circuit breaker can effectively improve the quality of test of relay protection and automatic safety devices.
出处 《实验室研究与探索》 CAS 北大核心 2014年第4期65-67,共3页 Research and Exploration In Laboratory
基金 2013年江苏省高等学校大学生实践创新计划(2012JSSPITP1953)
关键词 继电保护 测试 单片机 模拟 断路器 relay protection test microcontroller simulation circuit breaker
  • 相关文献

参考文献10

二级参考文献15

  • 1李娟,焦邵华.基于DSP的高压断路器状态在线监测装置[J].电力自动化设备,2004,24(8):44-47. 被引量:14
  • 2SchrammHH.西门子公司3AT型550kV断路器[J].高压电器,1996,32(5):47-52. 被引量:4
  • 3林永顺.电力牵引供变电技术[M].北京:中国铁道出版社,2006.
  • 4清华大学电子教研组.数字电子技术基础[M].北京:高等教育出版社,1984:57-121.
  • 5清华大学电子教研组.模拟电子技术基础[M].北京:高等教育出版社,1984:428-456.
  • 6刘学军.继电保护原理[M].北京:中国电力出版社,1997:144-170.
  • 7ispLSI1048E Data Sheets [ EB/OL]. http://www. Lattice.com,2002 - 02.
  • 8W78E516B Data Sheets [ EB/OL]. http ://www. winbond.com,2000- 12.
  • 9季建华,都志杰,吴勤勤.智能仪表原理、设计及调试[M].上海:华东理工大学出版社,1994.
  • 10严殊.单片微机多任务编程[J].微型机与应用,1997,16(9):47-48. 被引量:2