期刊文献+

Investigation of Mean Glandular Dose in Diagnostic Mammography in China 被引量:2

Investigation of Mean Glandular Dose in Diagnostic Mammography in China
下载PDF
导出
摘要 A survey of 420 exposures of mammography was performed with the parameters recorded. Entrance skin air kerma (ESAK) was measured and the mean glandular dose (MGD) was calculated according to the Dance's formula. Correlation analysis showed that several factors could affect the MGD level. Mann-whitney test and Non-parametric ANOVA analyses were used to compare the MGD level grouped by view type and radiographic systems, No significant difference was found in MGD between the craniocaudal (CC) group and the mediolateral oblique (MLO) group. The MGD level was higher in the CR group than in the other two groups. MGD was positively correlated with the compressed breast thickness (CBT). MGD varied with the half value layer (HVL) and increased first then decreased, The mean MGD level in China is about 1.6 mGy and is lower than the guidance level in the International Basic Safety Standards (IBSS). A survey of 420 exposures of mammography was performed with the parameters recorded. Entrance skin air kerma (ESAK) was measured and the mean glandular dose (MGD) was calculated according to the Dance's formula. Correlation analysis showed that several factors could affect the MGD level. Mann-whitney test and Non-parametric ANOVA analyses were used to compare the MGD level grouped by view type and radiographic systems, No significant difference was found in MGD between the craniocaudal (CC) group and the mediolateral oblique (MLO) group. The MGD level was higher in the CR group than in the other two groups. MGD was positively correlated with the compressed breast thickness (CBT). MGD varied with the half value layer (HVL) and increased first then decreased, The mean MGD level in China is about 1.6 mGy and is lower than the guidance level in the International Basic Safety Standards (IBSS).
出处 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2014年第5期396-399,共4页 生物医学与环境科学(英文版)
基金 supported in part by Science and Education Health Project of Jiangsu Province during the Twelfth-Five Plan Period(No.ZX201109) National Health Industry Research and Special Project(No.201002009)
关键词 MGD HVL Mean
  • 相关文献

参考文献10

  • 1Boyle P and Ferlay J.Cancer incidence and mortality in Europe, 2004.Ann Oncol, 2005; 16,481-8.
  • 2Dance DR, Young KC, and van Engen RE.Further factors for the estimation of mean glandular dose using the United Kingdom, European and IAEA breast dosimetry protocols.Phys Med Bioi, 2009; 54,4361-72.
  • 3Dance DR, Skinner CL, Young KC, et at, Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol.Phys Med Bioi, 2000; 45, 3225-40.
  • 4Tsapaki V, Tsalafoutas lA, Poga V, et al, Investigation of breast dose in five screening mammography centres in Greece.J Radiol Prot, 2008; 28, 337-46.
  • 5Jamal N, Ng KH, and McLean D.A study of mean glandular dose during diagnostic mammography in Malaysia and some of the factors affecting it.Br J Radiol, 2003; 76, 238-45.
  • 6Ciraj-Bjelac 0, Avramova-Cholakova S, Beganovic A, et al.Image quality and dose in mammography in 17 countries in Africa, Asia and Eastern Europe: results from IAEA projects.Eur J Radiol, 2012; 81, 2161-8.
  • 70duko J, Young K, and Burch A.A Survey of Patient Doses from Digital Mammography Systems in the UK in 2007 to 2009.2010; 6136,365-70.
  • 8Robinson M and Kotre CJ.Trends in compressed breast thickness and radiation dose in breast screening mammography.Br J Radiol, 2008; 81, 214-8.
  • 9McCuliagh JB, Baldelli P, and Phelan N.Clinical dose performance of full field digital mammography in a breast screening programme.Br J Radiol, 2011; 84, 1027-33.
  • 10Baldelli P, McCullagh J, Phelan N, et el.Comprehensive dose survey of breast screening in Ireland.Radiat Prot Dosimetry, 2011; 145, 52-60.