摘要 为研究空气源热泵的结霜与除霜特性,建立了热泵系统结霜动态模型和显热除霜模型,求解模型获得了结霜与除霜过程中各系统参数变化规律。结果表明,初期霜层对系统性能影响较小;当结霜工况运行70 min时,系统性能系数(COP)、制热量和蒸发压力降幅分别为6.9%、10.9%和12.3%;随着霜层继续生长,系统性能衰减加剧;除霜工况下,管壁温度迅速升高,霜层预热后进入融霜阶段,从蒸发器入口微元到出口微元,融霜时间从7 s增加到52 s;进入融霜水蒸发阶段后,管壁温度增速减慢,沿制冷剂流动方向融霜水蒸发时间逐渐增加;当换热器散热与得热达到平衡时,管壁温度维持恒定。 A dynamic frosting model and a sensible heat defrost model of air source heat pump system were developed to investigate the frost and defrost characteristics, the variation of system parameters under frosting and defrosting were obtained. The results show that, at the early stage of frosting, the frost has a slight effect on the system performance;after 70 minutes, the decrements of coefficient of performance (COP), heating capacity and evaporating pressure reached to 6.9%, 10.9%and 12.3%, respectively. The system performance reduced rapidly with the frost growing. Under defrost conditions, the frost changed into defrost stage after preheat as the wall temperature increased rapidly, and the defrost time of inlet section and outlet section increased from 7 seconds to 52 seconds. In the evaporation stage of defrosting water, the wall temperature growth decreases, and the evaporate time increases in the direction of flow of the refrigerant. When the heat gain and heat loss of the exchanger reach balance, the wall temperature finally maintained constant.
出处 《制冷技术》 2014年第1期18-25,共8页 Chinese Journal of Refrigeration Technology
基金 国家自然科学基金资助项目(51106023) "十二五"国家科技支撑计划资助项目(2011BAJ03B14) 江苏省自然科学基金重点资助项目(BK2010029)
关键词 空气源热泵 结霜特性 除霜特性 显热除霜 数值模拟 Air source heat pump Frosting characteristics Defrosting characteristics Sensible heat defrost Numerical simulation
  • 相关文献

参考文献13

  • 1YAO Y, JIANG Y Q, DENG S M. A study on the performance of the airside heat exchanger under frosting in an air source heat pump water heater/chiller unit[J]. International Journal of Heat and Mass Transfer, 2004, 47(17): 3745-3756.
  • 2姚杨,姜益强,马最良.翅片管换热器结霜时霜密度和厚度的变化[J].工程热物理学报,2003,24(6):1040-1042. 被引量:27
  • 3SEKER D, KARATAS H, EGRICAN N. Frost formation on fin-and-tube heat exchangers. Part I--Modeling of frost formation on fin-and-tube heat exchangers[J]. International Journal of Refrigeration, 2004, 27(4): 367- 374.
  • 4CHEN H, THOMAS L, BESANT R W. Fan supplied heat exchanger fin performance under frosting conditions [J]. International Journal of Refrigeration, 2003, 26 (1): 140- 149.
  • 5KRAKOW K I, LIN Sui, YAN Li. An idealized model of reversed-cycle hot gas defrosting[J]. ASHRAE Trans, 1993, 99(2): 317-328.
  • 6黄虎,李志浩,虞维平.风冷热泵冷热水机组除霜过程仿真[J].东南大学学报(自然科学版),2001,31(1):52-56. 被引量:21
  • 7KRAKOW K I, YAN Li, LIN Sui. A model of hot-gas defrosting of evaporators (Part I ): heat and mass transfer theory[J]. ASHRAE Trans, 1992, 98(1) :451-474.
  • 8HOFFENBECKER N, KLEIN S A, REINDL D T. Hot gas defrost model development and validation[J]. International Journal of Refrigeration, 2005, 28(4): 605- 615.
  • 9李九如,韩志涛,姚杨,姜益强,马最良.基于实验参数的空气源热泵除霜滞留表面水蒸发模型[J].上海交通大学学报,2008,42(6):989-992. 被引量:10
  • 10梁彩华,张小松.显热除霜方式的理论分析与试验研究[J].工程热物理学报,2006,27(4):559-561. 被引量:13

二级参考文献37

  • 1韩慧秋,董威.空气源热泵机组除霜问题分析[J].长春工程学院学报(自然科学版),2003,4(1):14-16. 被引量:2
  • 2姚杨,马最良.空气源热泵冷热水机组室外换热器结霜工况下数学模型的建立[J].流体机械,2001,29(10):50-52. 被引量:12
  • 3胡跃明,董玉军,周翔,包涛,袁秀玲.人字形波纹板式蒸发器数值模拟[J].制冷与空调,2005,5(2):42-46. 被引量:4
  • 4梁彩华,张小松,巢龙兆,刘一民.显热除霜方式与逆向除霜方式的对比试验研究[J].制冷学报,2005,26(4):20-24. 被引量:30
  • 5丁国良.小型制冷装置动态仿真与优化研究[学位论文].上海:上海交通大学动力系,1993..
  • 6Yi-Yie Yan, Tsing-Fa Lin. Evaporation heat transfer and pressure drop of refrigerant R134a in a plate heat exchanger[ J]. International Journal of Heat Transfer, 1999, ( 121 ) : 118-127.
  • 7Yi-Yie Yan, Hsiang-Chao Lio, Tsing-Fa Lin. Condensation heat transfer and pressure drop of refrigerantR134a in a plate heat exchanger[ J ]. International Journal of Heat and Mass Transfer, 1999, (42) :993- 1006.
  • 8S N Kondepudi, D L O'Neal. Performance of Finned-Tube Heat Exchangers under Frosting Conditions: I. Simulation Model. Int J of Refrig, 1993, 16(3): 175-180.
  • 9J Martinez-Prias, S M Aceves. Effects of Evaporator Frosting on the Performance of an Air-to-Air Heat Pump. ASME Trans, 1999, 121(1): 60-65.
  • 10S M Sami, T Duong. Mass and Heat Transfer during Frost Growth. ASHRAE Trans, 1989, 95(1): 158-165.

共引文献91

同被引文献267

引证文献31

二级引证文献159

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部