介绍了触发晶闸管采用的移相触发回路及过零触发回路,分析了它们存在的缺点。为了解决这一问题,介绍了新的综合式数字触发模块-ZCT模块,以及它的优越性和实际应用效果。
Traditionally, designers of SCR firing circuit phase-angle or zero-voltage firing circuit. Therefore must choose between two their defect is analysed, mode--ZCT Mode is developed. The superiority and practical application effect introduced modes of operation: a new hybrid firing of ZCT Model were introduced.