摘要 由于现场施工队伍多、施工工期短等问题,用100%TOFD+UT组合方式取代100%射线检测方式对现场组焊的球罐焊缝进行检测,并编制了检测技术方案。按照此方案对其中一台球罐完成TEFD检测,发现许多圆形、条形缺陷,经超声验证,其结果与TOFD检测出的缺陷位置基本吻合。 As the questions of many construction team and short construction period, 100% TOFD + UT was used to replace 100% ray detection, to detect welds of the spherical tanks, and wrote the detection scheme. According to the detection scheme, a spherical tank was detected, and many round, strip defects were found, by ultrasonic verification, the results of the detected defect positions were Basic same with TOFD detection.
出处 《中国化工装备》 CAS 2014年第3期45-48,共4页 China Chemical Industry Equipment
关键词 球罐 衍射时差法 超声检测 射线检测 检测方案 spherical tanks TOFD ultrasonic detection ray detection detection scheme