摘要 为了快速地对雷击输电线路类型进行识别,以直击雷产生的三相暂态电流行波为研究对象,基于EMTP仿真软件,建立了装有导线暂态电流监测设备的输电线路仿真模型。根据平行导线之间的耦合原理,通过判断雷击故障相数将直击雷初步分为3类。并通过提取各个子分类中的直击雷波形的时域与频域特征构建识别判据,最终实现输电线路直击雷的识别。仿真测试结果表明,对直击雷进行初步分类可有效区分雷击塔顶所造成的多相闪络情况,降低识别的难度。这种直击雷识别算法在不同雷电源参数、不同故障距离下均能对直击雷进行有效识别。 In order to identify lightning strikes hitting transmission lines, taking three-phase transient current travelling waves caused by direct lightning strike as the research object, we built a model of transmission line with equipment monitoring transient current in its conductors by the EMTP software. According to the principle of coupling between parallel conductors, we classified direct lightning strikes into three groups preliminarily based on the number of lightning-fault phases. From each category, we established criteria based on the time-domain and frequency-domain features of direct lightning strike waves, which were used to finally identify direct lightning strikes. The simulation results show that, the preliminary classification of direct lightning strikes can effectively distinguish multiphase flashover caused by lightning strike to the top of tower, and reduce the difficulty of identifying lightning strikes. The proposed identification method can recognize the direct lightning strikes with different strike positions and different lightning parameters.
出处 《高电压技术》 EI CAS CSCD 北大核心 2014年第5期1298-1305,共8页 High Voltage Engineering
基金 国家重点基础研究发展计划(973计划)(2009CB724504) 国家自然科学基金(51177176) 云南电力公司科技基金(K-YN2012-200)~~
关键词 输电线路 直击雷 模式识别 暂态电流行波 平行导线耦合系数 EMTP仿真 transmission line direct lightning strike pattern recognition transient current travelling waves coupling coefficient of parallel conductor EMTP simulation
  • 相关文献

参考文献14

二级参考文献168

共引文献283

同被引文献107

引证文献10

二级引证文献136

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部