支架影像增强显影技术在冠脉支架植入术中的应用效果观察 被引量:3

Effective observation of application of stent boost in coronary stent implantation
下载PDF
导出
摘要 目的评价支架增强显影(SB)技术在冠脉支架植入术中的应用效果。方法将204例行冠状动脉支架植入术的患者随机分为观察组和对照组,各102例。两组均采用常规冠状动脉造影方法行冠状动脉造影,并在其指导下进行冠状动脉支架植入术。对照组支架植入后采用QCA自动分析系统测量支架直径的相关参数(包括支架直径的最小值、最大值、均值)并计算支架偏心指数。同时进行支架可视性和球囊内扩张必要性评分。观察组在支架植入后行SB,测量上述指标并进行上述评分。观察组26例支架植入后行血管内超声(IVUS)检查,测量上述指标并进行上述评分。结果对照组支架植入后支架可视性得分低于观察组,P<0.05。对照组发现30处、观察组发现48处有球囊内扩张必要性而行支架球囊内扩张术。两组QCA、SB、IVUS测得植入支架最小直径、最大直径、直径均值和支架偏心指数差异无统计学意义。Pearson相关性分析显示QCA与SB、QCA与IVUS、SB与IVUS测得支架最小直径均有良好的相关性,r分别为0.772、0.775、0.782,P均<0.05。结论 SB可明显提高支架的可视性,有效指导支架的球囊内扩张,在测量支架直径方面甚至可以替代冠脉内超声。 Objective To evaluate the application effect of Stent Boost ( SB) in coronary stent implantation .Methods A total of 204 consecutive patients were randomly divided into the observation group (n=102) and control group (n=102). Coronary angiography were performed in the two group and coronary stents were implanted which were guided by coronary an -giography .Diameter parameters ( including maximum , minimum and average ) were measured by quantitative coronary angiog-raphy (QCA), the ratio (maximum stent diameter (MaxLD)-minimum stent diameter (MinLD))/MaxLD) was calculated. Stent visibility and the need for post dilatation was assessed at the same time .SB was performed after stent implantation and the parameters were measured in the observation group , stent visibility and the need for post dilatation was assessed .Twenty-six patients in the observation group were analyzed by IVUS at the same time .Results The score of stent visibility in the ob-servation group was lower than that of the control group (P〈0.05).Post dilation after stent implantation was performed in 48 cases of the observation group and 30 cases in the control group .QCA, SB, IVUS of the two groups measured that the mini-mum diameter, the maximum diameter , the average diameter and stent eccentricity index had no statistical significance .Pear-son correlation analysis showed that QCA and SB , QCA and IVUS, SB and IVUS were in good correlations ( r=0.772, 0.775, 0.782, respectively, all P〈0.05).Conclusion SB increases the stent visibility and effectively guides the post dil-atation.Meanwhile, SB can even take the place of IVUS in the term of measuring tent diameter .
出处 《山东医药》 CAS 2014年第14期8-10,共3页 Shandong Medical Journal
基金 河北省科技厅2012年度重点科技支撑计划项目(12276104D-53)
关键词 冠状动脉支架植入术 冠状动脉造影 血管内超声 支架增强显影 支架可视性 支架球囊球囊内扩张 coronary stent implantation coronary arteriography intravascular unltrasound Stent Boost stent visibil-ity post dilatation
  • 相关文献

参考文献4

二级参考文献18

  • 1Fischman DL, Leon MB, Baim DS, Schatz RA, Savage MR Penn I, et al. A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronaryartery disease. N Engl J Med. 1994; 331: 496-501.
  • 2Serruys PW, Ong AT, van Herwerden LA, Sousa JE, Jatene A, Bonnier JJ, et al. Five-year outcomes after coronary stenting versus bypass surgery for the treatment of multivessel disease: the final analysis of the Arterial Revascularization Therapies Study (ARTS) randomized trial. J Am Coil Cardiol 2005; 46: 575-581.
  • 3Fujii K, Mintz GS, Kobayashi Y, Carlier SG, Takebayashi H, Yasuda T, et al. Contribution of stent underexpansion to recurrence after sirolimus-eluting stent implantation for in-stent restenosis. Circulation 2004; 109: 1085-1088.
  • 4de Feyter PJ, Kay P, Disco C, Serruys PW. Reference chart derived from post-stent-implantation intravascular ultrasound predictors of 6-month expected restenosis on quantitative coronary angiography. Circulation 1999; 100: 1777-1783.
  • 5Mintz GS, Nissen SE, Anderson WD, Bailey SR, Erbel R, Fitzgerald PJ, et al. ACC clinical expert consensus document on standards for the acquisition, measurement and reporting of intravascular ultrasound studies: a report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents (Committee to Develop a Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS)). J Am Coil Cardiol. 2001; 37: 1478-1492.
  • 6Koolen JJ, van het Veer M, Hanekamp CE. StentBoost image enhancement: first clinical experience. Medicamundi 2005; 49: 1-6.
  • 7Smith SC Jr, Feldman TE, Hirshfeld JW Jr, Jacobs AK, Kern MJ, King SB III, et al. ACC/AHA/SCAI 2005 guideline update for percutaneous coronary intervention--summary article: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/SCAI writing committee to update the 2001 guidelines for percutaneous coronary intervention). Circulation 2006; 113: 156-175.
  • 8Serruys PW, Reiber JH, Wijns W, van den Brand M, Kooijman CJ, ten Katen HJ, et al. Assessment of percutaneous transluminal coronary angioplasty by quantitative coronary angiography: diameter versus densitometric area measurements. Am J Cardiol 1984; 54: 482-488.
  • 9Tanabe K, Serruys PW, Degertekin M, Grube E, Guagliumi G Urbaszek W, et al. Incomplete stent apposition after implantation of paclitaxel-eluting stents or bare metal stents: insights from the randomized TAXUS II trial. Circulation 2005; 111:900-905.
  • 10Rogers PK, Michaels AD. Enhanced X-ray visualization of coronary stents: clinical aspects. Cardiol Clin 2009; 27: 467-475.

共引文献14

同被引文献12

引证文献3

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部