天津铁厂4号高炉热风炉改造前存在着总蓄热面积、炉容蓄热面积小,风温低设备隐患多等现象。通过技术改造后。增加了总蓄热面积和炉容面积,增强了严密性,减少了漏风,提高了风温及高炉利用系数,创造了历年最好生产水平。
The phenomena such as small total regenerative area and that of furnace volume , low air temperature and much hidden trouble of equipment exist in 4 B.F. hot stove of Tianjin Iron Plant before modification. By modifying, total regen-erative area and furnace volume area are increased, tightness strengthened, leak air reduced, air temperature and utilization coefficient improved and the best production level of history has been created.
出处
《天津冶金》
CAS
2001年第1期41-42,共2页
Tianjin Metallurgy
关键词
高炉
热风炉
热风温度
技术改造
炼铁
B.F. hot stove modification hot air temperature effect