期刊文献+

多层螺旋CT与冠状动脉造影在心肌桥-壁冠状动脉成像诊断中的对比研究 被引量:3

Comparative research with MSCT and CAG in the myocardial bridge-wall diagnostic coronary angiography
下载PDF
导出
摘要 目的:对比分析多层螺旋CT(MSCT)与冠状动脉造影(CAG)在心肌桥-壁冠状动脉成像诊断中应用价值。方法:选取经确诊的心肌桥-壁冠状动脉(MB-MCA)患者93例,对其进行导管CAG和MSCT扫描,比较两种检查手段的诊断准确性,并对其结果进行相关性分析。结果:MSCT和CAG两种检查手段在诊断表浅型和深埋型MB-MCA中具有高度的一致性,在诊断MBMCA平均长度、平均深度上比较具有统计学意义(t=3.021,t=3.758;P<0.05),狭窄检出率比较无差异。结论:MSCT作为一种新型、无创的MB-MCA检查手段,其诊断结果可靠、准确,能够为临床医生提供更加丰富的诊断信息,可广泛应用于MB-MCA临床诊断中。 Objective: To comparative Research with MSCT and CAG in the myocardial bridgewall diagnostic coronary. Methods: Selected 93 patients for the study in January 2011 to the end of December 2013,MB-MCA patients diagnosed in Beijing North Hospital, all patients underwent catheter coronary angiography(CAG) and 64-slice spiral CT(MSCT), comparison of the diagnostic accuracy of the two inspection methods, and the results of the correlation analysis, results processing and analysis using statistical software SPSS17.0. Results: MSCT and CAG were two examination methods in the diagnosis of superficial and deep type MB-MCA, witha high degree of consistency in the diagnosis of MB-MCA average length, average depth comparison with statistical significance(t=3.021, t=3.758; P〈0.05), there was not statistically significant comparison in the narrow detection rate. Conclusion: MSCT as a novel, non-invasive means of MB-MCA examination, the diagnosis results are reliable, accurate and capable of providing a richer diagnostic information for clinicians, clinician and patient can be widely applied.
出处 《中国医学装备》 2014年第5期90-92,共3页 China Medical Equipment
关键词 心肌桥-壁冠状动脉 多层螺旋CT 导管冠状动脉造影术 Myocardial bridge-mural coronary artery Multislice spiral CT Catheter coronary angiography
  • 相关文献

参考文献15

二级参考文献126

共引文献136

同被引文献34

  • 1Martinek M,Nesser HJ,Aichinger J,et al.Accuracyof intergration of multislice computed tomographyimaging into three-dimensional electroanatomicmapping for real-time guided radiofrequencyablation of left atrial fibrillation-influence ofheart rhythm and radiofrequency lesions[J],JInterv Card Electrophysiol, 2006,17(2) : 85-92.
  • 2Cleland JG,Daubert JC,Erdmann E,et al.Theeffect of cardiac resynchronization on morbidityand mortality in heart failure[J].N Engl JMed,2005,352(15): 1539-1549.
  • 3Mlynarski R,Sosnowski M,Wlodyka A,et al.A user-friendly method of cardiac venoussystem visualization in 64-slice computedtomography[J]. Pacing Clin Electrophysiol,2009,32(3):323-329.
  • 4Jongbloed MR,Lamb HJ,Bax JJ,et al.Nonin-vasive visualization of the cardiac venous systemusing multislice computed tomography[J]. J AmColl Cardiol, 2005,45(5) : 749-753.
  • 5Gene B,Solak A,Sahin N,et al.Assessment ofthe coronary venous system by using cardicCT[J].Diagn Interv Radiol,2013,19(4):286-293.
  • 6Torres FS,Crean AM,Nguyen ET,et al.Abolitionof respiratory-motion artifact in computedtomography coronary angiography with ultrafastexaminations:a comparison between 64-row and320-row multidetector scanners[J].Can AssocRadiol J,2010,61(1):5-12.
  • 7Dewey M,Zimmermann E,Deissenrieder F,et al.Noninvasive coronary angiography by 320-row computed tomography with lower radiationexposure and maintained diagnostic accuracy :comparison of results with cardiac catheterizationin head-to-head pilot investigation[J]. Circulation,2009,120(10):867-875.
  • 8Defranee T,Dubois E,Gebow D,et al.Helicalprospective ECG-gating in cardiac computedtomography : radiation dose and image quality[J].Int J Cardiovasc Imaging,2010,26(1):99-107.
  • 9Mlynarski R,Sosnowski M,Wlodyka A,et al.Optimal image reconstruction intervals fornoninvasive visualization of the cardiac venoussystem with a 64-slice computed tomography [J].Int J Cardiovasc Imaging,2009,25(6):635-641.
  • 10Schart SM, Bromberger-Barnea B , PermuttS.Distribution of coronary venous flow[J].JAppl Physiol, 1971,30(5) : 657-662.

引证文献3

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部