摘要 目的分析金标免疫层析检测技术(GICA)、酶联免疫吸附测定(ELISA)和时间分辨免疫荧光分析(TRFIA)检测乙型肝炎病毒表面抗原(HBsAg)的结果。方法采用GICA、ELISA及TRFIA对11 058例标本进行HBsAg检测。结果 GICA、ELISA及TRFIA法检测11 058例标本HBsAg的阳性率分别为15.52%、15.64%及15.95%,两两比较,差异无统计学意义(P〉0.05)。TRFIA定量检测为0.2~〈2.0ng/mL时,GICA、ELISA的诊断符合率分别为25.0%、75.0%。结论检测HBsAg低浓度样本时,GICA和ELISA的诊断符合率降低。 Objective To analyze the results of gold labeled immunochromatographic assay (GICA ) ,enzyme-linked immunosor-bent assay (ELISA ) and time resolved fluoroimmunoassay (TRFIA ) detection for hepatitis B virus surface antigen (HBsAg ) . Methods GICA ,ELISA and TRFIA were employed to conduct the HBsAg testing in 11 058 specimens .Results The HBsAg posi-tive rates of GICA ,ELISA and TRFIA detection in 11 ,058 specimens were 15 .52% ,15 .64% and 15 .95% ,respectively ,with no statistically significant difference when pairwise comparison performed (P〉0 .05) .In specimens which results of TRFIA quantita-tive detection was 0 .2- 〈2 .0 ng/mL ,the diagnostic compliance rates of GICA ,ELISA were 25 .0% and 75 .0% ,respectively .Con-clusion The diagnostic compliance rates of GICA ,ELISA detection in specimens with low concentration HBsAg are deceased .