摘要
针对 CO锅炉省煤器泄漏问题 ,从设备结构、材质、工艺流程及运行工况等方面进行了综合分析 ,并对其结构进行了技术改造 ,从根本上解决了设备的隐患。经改造后几年的生产实践证明 ,效果很好。
In accordance with the leakage problem of CO boiler economizer,the comprehensive analysis was conducted from the fields of structural feature,material and process flow sheet.The technical reconstruction of its structure was carried on.The hidden trouble of equipment was settled thoroughly.After reconstruction the effectiveness was good proved by production practice for several years.
出处
《石油化工设备技术》
CAS
2001年第1期36-38,共3页
Petrochemical Equipment Technology