摘要 双馈异步发电机定子绕组发生不对称故障时,会在转子电流信号中引发一定的谐波分量。由于早期故障引起的故障特征信号十分微弱,如何准确提取故障特征量已经成为一个很重要的课题。本文在动模实验室进行了双馈机定子绕组故障模拟实验,获取了正常及定子绕组不对称故障情况下的转子电流信号,然后采用傅里叶变换、小波变换、希尔伯特-黄变换(HHT)三种方法提取其故障特征量,进行灵敏度与可靠性的比较。通过对比可知,希尔伯特-黄变换提取出的故障特征量比傅里叶变换及小波变换的特征量更加敏感、可靠。 Asymmetric faults of doubly-fed wind power generator stator winding cause the harmonic component in the signal of rotor current. How to accurately extract fault feature has become a very important taskdue to the weak fault signal of early failure. This paper built the experimental platform of stator faults diagnosis in laboratory. The rotor current was derived in both normal and stator fault conditions, then the Fouriertransform, wavelet transform, Hilbert-Huang transform were used to extract the fault feature. By comparingthe sensitivity and reliability, fault feature of Hilbert-Huang transform is more sensitive, reliable than theFourier transform and wavelet transform.
出处 《微电机》 北大核心 2014年第5期66-70,共5页 Micromotors
基金 国家自然科学基金项目(51177039) 教育部博士点基金项目(20090944110011)
关键词 双馈异步发电机 故障检测 实验平台 转子电流 希尔伯特-黄变换 double-fed induction generator fault diagnosis experimental platform rotor current Hilbert-Huang transform
  • 相关文献

参考文献10

  • 1李辉,赵猛,赵斌,唐显虎,刘志详.双馈风电机组关键传感器的故障诊断方法[J].中国电机工程学报,2011,31(6):73-78. 被引量:22
  • 2舒进,张保会,李鹏,汪成根,程临燕,薄志谦,A. KLIMEK,褚云龙.变速恒频风电机组运行控制[J].电力系统自动化,2008,32(16):89-93. 被引量:46
  • 3Yazidi A, Capolino G A, Casadei D, et al. Simulation of Double- fed Induction Machine for Wind Turbine Generator Fault Analysis [ C ]. IEEE Symposium on Diagnostics for Electric Machine, 2005.
  • 4Stefani A, Yazidi A, Rossi C, et al. Doubly Fed Induction Ma-chines Diagnosis Based on Signature Analysis of Rotor Modulating Signals[ J]. IEEE Transactions on Industry Application, 2008, 44 (6): 1711-1721.
  • 5Shah D, Nandi S, Neti P. Stator Inter-turn Fault Detection of Dou- bly Fed Induction Generators Using Rotor Current and Search Coil Voltage Signature Analysis[ J] , IEEE Transactions on Industry Ap- plications, 2009: 1831-1842.
  • 6万书亭,李和明,许兆凤,李永刚.定子绕组匝间短路对发电机定转子径向振动特性的影响[J].中国电机工程学报,2004,24(4):157-161. 被引量:65
  • 7Penman J, Sedding H G, Lloyd B A, et al. Detection and Location of Interturn Short Circuits in the Stator Windings of Operating Motors [J]. IEEE transactions on Energy conversion, 1994, 9 (4): 652-658.
  • 8马宏忠,张志艳,张志新,钱雅云.双馈异步发电机定子匝间短路故障诊断研究[J].电机与控制学报,2011,15(11):50-54. 被引量:52
  • 9Huang N E, Shen Z, Long S R, et al. The Empirical Mode Decom- position and the Hilbert Spectrum for Nonlinear and Non-stationary Time Series Analysis [ J ]. Proceedings of the Royal Society of Lon- don. Series A: Mathematical, Physical and Engineering Sciences, 1998, 454(1971 ): 903-995.
  • 10陈继宁,马宏忠,时维俊,陈涛涛.基于希尔伯特-黄变换的双馈异步风力发电机定子故障诊断研究[J].大电机技术,2013(2):34-38. 被引量:9