以攀钢电网为实例,介绍小电阻接地系统的配置方式,分析小电阻接地系统在实际应用中存在的问题,提出相应的解决办法,为其它配电系统采用小电阻接地方式提供借鉴。
Taking Pangang power system as an example, the paper introduces configuration method of low resistance grounding system and the application problems of low resistance grounding system are analyzed; the corresponding solutions are proposed; it provides a reference for the low resistance grounding mode in other distribution system.