期刊文献+

600MW机组锅炉暖风器改造

Boiler Air Heater Transformation on 600 MW Unit
下载PDF
导出
摘要 针对北方联合电力有限责任公司达拉特发电厂600 MW机组锅炉原设计鳍片式暖风器及其系统存在易积灰堵塞、内漏、振动等问题,决定将暖风器改造为旋转式暖风器。改造后的旋转式暖风器通过定期旋转,不仅可以减少积灰的污染,提高换热效率,保证空预器入口风温达到设计值,而且可以大大减少风系统阻力,降低风机耗电量,消除了因进风温度低造成的风机失速抢风、空预器动静摩擦等安全隐患,同时取得了较好的经济效益。 it was decided that the air heater of the boiler on 600 MW unit should change from the fin-type to the rotation-type in Dalate Power Plant of North United Power Co.,I,td, because of the problem of easy ash deposition, inner leakage and vibration. After the transfi)rmation, the rotation-type air heater not only reduce the pollution of the ash deposition, promote the heat exchange efficiency, make sure the temperature of the air in the inlet of the air pre-heater achieve the design value, but also decrease the resistance in the air system greatly, reduce the power consumption of the fan, solve the hidden dangers of the fan stall, dynamic and static parts friction of the air pre-heater which are caused by the low inlet air temperature, at the same time get better economic benefit.
作者 闫海琼
出处 《内蒙古电力技术》 2014年第2期73-76,共4页 Inner Mongolia Electric Power
关键词 旋转式暖风器 空预器入口风温 风系统阻力 风机电流 rotation-type warm air heater inlet air temperature of air pre-heater resistance of air system fan current