摘要 目的探讨超声造影肝实质灌注峰值强度反映肝硬化肝实质的血流灌注变化的可行性。方法 35例肝硬化患者(病例组),21例健康人(对照组)进行超声造影检查,应用QLAB分析软件,将肝实质作为感兴趣区绘制时间-强度曲线,测量肝实质灌注峰值强度(Ipeak)。比较两组间Ipeak有无差异,并应用受试者操作特性(ROC)曲线进行分析。结果病例组与对照组比较,病例组的Ipeak小于正常组(P<0.05)。当Ipeak诊断肝硬化的界值为30.20 dB时,灵敏度为90.4%,特异度为74.8%。结论肝硬化患者和正常人之间超声造影Ipeak存在显著差异。Ipeak可以反映肝硬化肝脏血流灌注的变化,对判断有无肝硬化有着较高的灵敏度和特异度。 Objective To evaluate the pracfibility of peffusion assessed by contrast - enhanced ultrasouography (CEUS) for accurately and non - invassively predicting cirrhosis. Methods Thirty - five patients with cirrhosis and twenty - one healthy controls were given with CEUS examination, and time - intensity curves (TIC) were drawn as the regions of interest localities in liver parenchyma by using QLAB analyzing soft ware. The parameters of these two groups were as follows : peak intensity of liver parenchyma (Ipeak) by independent - samples t test, and the diagnostic value of parameters were analyzed by receiver operating characteristic (ROC) curve. Results Ipeak was smaller in cirrhosis patients than that of controls, the difference was statistically significant. The critical value of Ipeak was 30.20 and when it used for diagnosis of cirrhosis, its sensitivity reached 90.4% and its specificity was 74.8%. Conclusion CEUS can reflect the changes in blood perfusion of liver in cirrhotic patients. The parameter Ipeak of CEUS is significantly different between these two groups and it can be used as non - invasive parameter for diagnosis of cirrhosis.
作者 张金辉
出处 《临床和实验医学杂志》 2014年第11期932-934,共3页 Journal of Clinical and Experimental Medicine
关键词 肝硬化 超声造影 肝实质灌注 无创 Cirrhosis Contrast enhanced ultrasonography (CEUS) Peak intensity of liver parenchyma(Ipeak) Non -invasive
  • 相关文献

参考文献6

二级参考文献37

  • 1PingLiu Yun-HuaGao Kai-BinTan ZhengLiu SongZuo.Grey scale enhancement of rabbit liver and kidney by intravenous injection of a new lipid-coated ultrasound contrast agent[J].World Journal of Gastroenterology,2004,10(16):2369-2372. 被引量:3
  • 2迟宝荣,张英男,徐文贵,王成,杨冬艳,李中军,孙春华,高凤桐.核素动态显像肝血流量测定对肝硬化疾病的临床价值[J].中华核医学杂志,1996,16(1):52-53. 被引量:4
  • 3王红,黄岚.超声心肌声学造影与冠状动脉造影评价侧支循环的优势及意义[J].中华老年心脑血管病杂志,2006,8(2):141-142. 被引量:6
  • 4Blomley MJ,Lim AK,Harvey CJ,et al.Liver microbubble transit time compared with histology and Child-Pugh score in diffuse liver disease:a cross sectional st udy.Gut,2003,52:1188-1193.
  • 5Ridolfi F,Abbattista T,Marini F,et al.Contrast-enhanced ultrasound to evaluate the severity of chronic hepatitis C.Digest Liver Dis,2007,39:929-935.
  • 6French METAVIR Cooperative Study Group.Intraobserver and interobserver variations in liver biopsy interpretation in patients with chronic hepatitis C.Hepatology,1994,20:15-20.
  • 7Gulberg V,Haag K,Rossle M,et al.Hepatic arterial buffer response in patients with advanced cirrhosis.Hepatology,2002,35:630-634.
  • 8Miles KA,Hayball MP,Dixon AK.Functional images of hepatic perfusion obtained with dynamic CT.Radiology,1993,188:405-411.
  • 9Bravo AA,Sheth SG,Chopra S.Liver biopsy.N Engl J Med,2001,344:495-500.
  • 10Lin JH,Kim EY,Lee WJ,et al.Regenerative nodules in liver cirrhosis: findings at CT during arterial portography and CT hepatic arteriography with histopathologic correlation[J].Radiology,1999,210(2):451.

共引文献33

同被引文献31

  • 1Kim MY, Baik SK, Park DH, et al. Damping index ofdoppler hepatic vein wave form to assess the severity of por- tal hypertension and response to propranolol in liver cirrho- sis : a prospective nonrandomized study[ J] .Liver Int ,2007, 27(8) :1103: 1110.
  • 2Bertolotto M, Serafini G, Sconfienza L M, et al. The use of CEUS in the diagnosis of retinal/choroidal detachment and associated intraocular masses-preliminary investigation in patients with equivocal findings at conventional ultra- sound[ J]. Ultraschall Med, 2014, 35 (2) : 173-180.
  • 3陈敏.实时超声造影技术与病理对照评价肝纤维化分期的实验研究. 山西:山西医科大学,2013.
  • 4Ishibashill,Maruyama H,Takahashi M,et al. Assessment ofhepatic fibrosis by analysis of the dynamic behaviour ofmicrobubbles during contrast ultrasonography. Liver Int,2 0 1 0,3 0 : 1355-1363.
  • 5Li N,Ding H,Fan P,et al. Intrahepatic transit time predicts liver fibrosis in patients with chronic hepatitis B: quantitativeassessment with contrast-enhanced ultrasonography.Ultrasound Med Biol,2 0 1 0,3 6 : 1066-1075.
  • 6Wagnetz U , Atri M, Massey C, et al Intraoperative ultrasoundof the liver in primary and secondary hepatic malignancies :comparison with preoperative 1. 5-T MRI and 64-MDCT. Am JRoentgenol,2 0 1 1,1 9 6: 562-568.
  • 7廖沁,周希瑗.超声微泡造影剂在眼科的研究进展[J].眼科新进展,2008,28(3):238-240. 被引量:3
  • 8杨琼,魏文斌,杨文利,史雪辉,周丹,刘妍.Sono Vue实时超声造影对脉络膜视网膜结构及功能影响的实验研究[J].眼科,2008,17(3):193-197. 被引量:21
  • 9李海东,傅培.超声造影在眼科研究中的应用[J].国际眼科纵览,2010,34(2):94-97. 被引量:13
  • 10裴书芳,丛淑珍,冯占武,甘科红,周立峰,李康.实时组织弹性成像诊断肝纤维化[J].中国医学影像技术,2010,26(5):893-895. 被引量:72