期刊文献+

Array多焦点人工晶状体的初步观察 被引量:13

Preliminary clinical observation of Array multifocal intraocular lens implantation
下载PDF
导出
摘要 目的 初步评估 Array多焦点人工晶状体的有效性。方法 从我院住院的白内障患者中选择合适的病例 ,男 4例 4眼 ,女 6例 7眼 ,行标准超声乳化白内障摘出术联合Array人工晶状体植入术 ,观察患者术后的远、近视力 ,角膜曲率 ,及视觉症状。结果 术后最好视力平均值 :非矫正远视力为 0 .8,最佳矫正远视力为 0 .9,非矫正近视力为 0 .5 ,用视远的矫正度数矫正的近视力为 0 .6 ,最佳矫正近视力为 0 .9。角膜散光术前及术后均小于1.5 D。1例 (9.1% )患者夜间有眩光。结论  Array人工晶状体可以同时提供良好的远视力和近视力 。 Objective To evaluate the clinical effects of Array multifocal intraocular lens.Methods Ten cases (11 eyes) of cataract patients, including 4 males (4 eyes) and 6 females(7 eyes), were involved in this study. All patients underwent standard phacoemulsification with Array multifocal intraocular lens implantation. The complications during operation, postoperative distant visual acuity, near visual acuity, corneal curvature and visual symptoms were observed. Results The mean value of best postoperative visual acuity was recorded as follows: uncorrected distant visual acuity was0 8, the best corrected distant visual acuity was 0.9, uncorrected near visual acuity was 0.5, near visual acuity with distant corrected was 0 6, the best corrected near visual acuity was 0.9. The astigmatism of cornea was less than 1 5D pre operatively and post operatively. One patient (9.1%) complained glare. Conclusion Array multifocal intraocular lens can provide good distant and near visual acuity. With more cases and longer follow up, we can draw a further conclusion.
出处 《眼科新进展》 CAS 2001年第1期30-32,共3页 Recent Advances in Ophthalmology
关键词 超声乳化术 多焦点人工晶状体 白内障 ARRAY ultrasonic phacoemulsification multifocal intraocular lens cataract
  • 相关文献

参考文献16

  • 1[1]Steinert RF, Aker BL, Trentacost DJ, et al. A prospective comparative study of the AMO ARRAY zonal-progressive multifocal silicone intraocular lens and a monofocal intraocular lens [J]. Ophthalmology 1999; 106(7)∶1243-1255.
  • 2[2]Brydon KW, Tokarewicz AC, Nichols BD. AMO array multifocal lens versus monofocal correction in cataract surgery [J]. J Cataract Refract Surg 2000; 26(1)∶96-100.
  • 3[3]Arens B, Freudenthaler N, Quentin CD. Binocular function after bilateral implantation of monofocal and refractive multifocal intraocular lenses [J]. J Cataract Refract Surg 1999; 25(3)∶399-404.
  • 4[4]Negishi K, Bissen Miyajima H, Kato K, et al. Evaluation of a zonal-progressive multifocal intraocular lens [J]. Am J Ophthalmol 1997; 124(3)∶321-330.
  • 5[5]Javitt JC, Wang F, Trentacost DJ, et al. Outcomes of cataract extraction with multifocal intraocular lens implantation: functional status and quality of life [J]. Ophthalmology 1997; 104(4)∶589-599.
  • 6[6]Weghaupt H, Pieh S, Skorpik C. Comparison of pseudoaccommodation and visual quality between a diffractive and refractive multifocal intraocular lens [J]. J Cataract Refract Surg 1998; 24(5)∶663-665.
  • 7[7]Walkow T, Liekfeld A, Anders N, et al. A prospective evaluation of a diffractive versus a refractive designed multifocal intraocular lens [J]. Ophthalmology 1997; 104(9)∶1380-1386.
  • 8[8]Vaquero Ruano M, Encinas JL, Millan I, et al. AMO array multifocal versus monofocal intraocular lenses: long-term follow-up [J]. J Cataract Refract Surg 1998; 24(1)∶118-123.
  • 9[9]Ravalico G, Parentin F, Pastori G, et al. Spatial resolution threshold in pseudophakic patients with monofocal and multifocal intraocular lenses [J]. J Cataract Refract Surg 1998; 24(2)∶244-248.
  • 10[10]Pieh S, Weghaupt H, Skorpik C. Contrast sensitivity and glare disability with diffractive and refractive multifocal intraocular lenses [J]. J Cataract Refract Surg 1998; 24(5)∶659-662.

同被引文献140

引证文献13

二级引证文献47

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部