摘要 以沉淀白炭黑、气相白炭黑和MQ树脂负载荧光指示剂Ru(dpp)3Cl2,添加到二甲基硅橡胶,制备氧敏感荧光膜,研究指示剂载体和用量对荧光膜荧光输出的影响。结果表明:纯硅橡胶荧光膜的荧光输出很低,SiO2填料可作荧光指示剂的载体提高指示剂的分散和荧光效率,SiO2填料提高荧光效率的能力为MQ树脂>气相白炭黑>沉淀白炭黑。含10%SiO2载体的硅橡胶制备的荧光膜,其荧光输出随指示剂用量线性增加,直至指示剂用量达0.1%,但SiO2填料降低荧光膜的响应速度。 Precipitated silica, fumed silica and synthesized MQ resin were adopted to adsorb phosphor Ru(dpp)3C12 ,and the pigmented fillers were mixed with polydimethylsiloxane to fabricate oxygen-sensitive fluorescent membranes. The effects of the SiO2 filler type and phosphor content on the performance of the fluorescent membranes were investigated. The fluorescence output of the membrane without fillers was very poor. SiO2 fillers could function as phosphor carriers to improve the dispersing of the phosphor and enhance the fluorescence efficiency of the phosphor. In regard to the enhancement capacity, the SiO2 fillers could be ranked in MQ resin, fumed silica and precipitated silica. Filled with 10% of SiO2, the fluorescence output of the membranes increased lineally with phosphor content as the content was below 0.1%. But SiO2 carriers reduced the response speed of the membranes to dissolved oxygen content.
出处 《分析科学学报》 CAS CSCD 北大核心 2014年第3期347-351,共5页 Journal of Analytical Science
关键词 溶解氧传感器 指示剂载体 聚二甲基硅氧烷 荧光膜 邻菲咯啉钌 Dissolved oxygen sensor Phosphor carrier PDMS Fluorescent membrane Ru (dpp) 3 C12
  • 相关文献

参考文献15

二级参考文献116

共引文献75

同被引文献30

  • 1吴宇雄,周尽花,赵鸿斌.5-氨基-1,10-邻菲罗啉的合成研究[J].精细石油化工,2004,21(4):7-9. 被引量:7
  • 2胡静,吕凤婷,房喻.光学薄膜氧气传感器研究进展[J].化学研究与应用,2007,19(5):457-464. 被引量:7
  • 3Zhou Y J,Zhang J H,Gu Y,Cai X X.Oxygen permeable silicon-based polymer[J].Chemical New Materials,1996,1:8-11.
  • 4Lu X,Manners I,Winnik M A.Polymer/silica composite films as luminescent oxygen sensors[J].Macromolecules,2001,34(6):1917-1927.
  • 5Xiao D,Mo Y,Choi M M F.A hand-held optical sensor for dissolved oxygen measurement[J].Measurement Science and Technology,2003,14(6):862-867.
  • 6Xing S M,Wang Y L.Synthetic Process and Application of Organic Silicon Products[M].Beijing:Chemical Industry Press,2000.
  • 7McDonagh C,Koller C,Mcevoy A K.Phase fluorometric dissolved oxygen sensor[J].Sensors and Actuators B,2001,74(1/3):124-130.
  • 8Jin P W. Guo Z Q, Zhu J, et al. Screen-printed red luminescent co- polymer film containing cyclometalated iridium ( HI ) complex as a high-permeability dissolved-oxygen sensor for fermentation biopro- cess[J]. Ind Eng Chem Res, 2013,52 ( 11 ) : 3980.
  • 9Shiotsuka M, Ueno Y, et al. Synthesis and photophysieal characte- rization of ruthenium( II ) and platinum( I] ) complexes with bis-pyri- dylethynyl-phenanthroline ligands as a metalloligand[J]. Transition Metal Chem, 2015,40(6) : 673.
  • 10Keefe M H, Benkstein K D, Hupp J T. Luminescent sensor mole- cules based on coordinated metal: A review of recent developments [J]. Coordination Chem Rev, 2000,205 : 201.

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部