摘要
针对地下工程中高湿度条件下测量仪器的工作时间短、防氡效果评价难的问题,提出了一种快速评价方法。在密闭的地下工程试验房中,氡的实测浓度由即时本底理论衰变浓度和未屏蔽部分组成,结合初浓度便可计算出屏蔽率。实验表明,得到的地下工程屏蔽率随时间变化而保持一定的稳定,实测的相对标准偏差为3.95%,可以通过短时间内测得的屏蔽率作为最终屏蔽率,从而实现地下工程特殊条件下的氡防护效果快速测定和评价。在地面实验室采用局部静态法进行了对比实验,得到的氡屏蔽率基本相符。
Background: It's difficult to evaluate the radon prevention effect because of the short operating time of measuring instrument under the circumstances of high humidity in underground construction. Purpose: A new rapid method to evaluate the radon prevention efficiency of underground construction was introduced. Methods: The radon concentrations before and after shielding operation were determined, and according to the regularity of radon decay, the shielding rate can be calculated. Results: The results showed that radon shielding rate in underground construction remains generally stable with variation of time, and the actual relatively standard deviation was 3.95%. So the rapid determination and evaluation of radon preventing effect under special conditions in underground construction can be realized by taking shielding rate in a short time for the final shielding rate. Compared with those by the local static method in ground lab, the results were similar. Conclusion: This paper provided a prompt, accurate and practicable way for the evaluation of radon prevention in underground construction, having a certain reference value.
出处
《核技术》
CAS
CSCD
北大核心
2014年第6期72-76,共5页
Nuclear Techniques
关键词
地下工程
防氡效果
评价方法
Underground construction, Radon preventing effect, Evaluation method