氧化铝玻璃复合体与Vita alpha饰瓷匹配性的研究 被引量:7

Research on the matching between alumina glass composite and Vita alpha veneering ceramic
原文传递
导出
摘要 目的 考察作者自制的氧化铝玻璃复合体与Vitaalpha饰瓷的匹配性。方法 采用热冲击试验与扫描电镜观察 ,分析研究氧化铝玻璃复合体与Vitaalpha饰瓷的匹配性。结果 抗热冲击温度ΔT平均为 170℃ ;扫描电镜观察结果显示Vitaalpha饰瓷与氧化铝玻璃复合体结合紧密 ,界面实现了瓷 瓷融合。 Objective To investigate the matching between selfmade alumina glass composite and Vita alpha veneering ceramic. Methods By using thermal shock test and SEM. Results The crazing resistance of alumina glass composite via Vita alpha ceramic expressed as the mean ΔT was 170 ℃. SEM micrograph indicate that Vita alpha ceramic fused to alumina glass composite, and no crack between the combination interface. Conclusion alumina glass composite can match to the Vita alpha ceramic fairly.
出处 《中华口腔医学杂志》 CAS CSCD 北大核心 2001年第2期122-123,T004,共3页 Chinese Journal of Stomatology
基金 国家教委中国博士后基金资助项目
关键词 牙科材料 扫描电镜 氧化铝玻璃复合体 Vita-alpha饰瓷 匹配性 Dental material Scanning electron microscope Alumina glass composite
  • 相关文献

参考文献4

  • 1骆小平,赵云风,巢永烈,田杰谟,张云龙,张世新.牙科用氧化铝玻璃复合材料的基础研究[J].实用口腔医学杂志,1998,14(1):3-5. 被引量:10
  • 2骆小平,实用口腔医学杂志,1998年,14卷,3页
  • 3Bindl A,Quintessen,1996年,47卷,775页
  • 4Anusavice K J,J Dent Res,1989年,68卷,1182页

共引文献9

同被引文献49

  • 1刘梦桃,贾安琦,张庆鸿.金瓷混合涂层烧结温度对镍铬合金与瓷结合强度的影响[J].实用口腔医学杂志,2005,21(3):412-414. 被引量:2
  • 2万乾炳,薛淼,游伦,杜传诗,巢永烈.粉浆涂塑铝瓷冠的匹配性研究[J].上海口腔医学,1997,6(1):17-19. 被引量:2
  • 3Rusin RP. Properties and applications of a new composite block for CAD/CAM[J]. Compend Contin Educ Dent, 2001, 22(6 Suppl) : 35-41.
  • 4al-Shehri SA, Mohammed H, Wilson CA. Influence of lamination on the flexural strength of a dental castable glass ceramic [J]. J Prosthet Dent, 1996, 76(1):23-28.
  • 5Mora GP, O'Brien WJ. Thermal shock resistance of core reinforced all-ceramic crown systems[J]. J Biomed Mater Res, 1994, 28(2) : 189-194.
  • 6Fischer H, Weber M, Marx R. Life time prediction of all ceramic bridges by computational methods [ J ]. J Dent Res, 2003, 82(3): 238-242.
  • 7King BW, Tripp HP, Duckworth WH. Nature of adherence of porcelain enamels to metals[J].J Am Ceram Soc, 1959, 42( 11 ) :504 -509.
  • 8Fleming GJ, Nolan L, Harris JJ. The in-vitro clinical failure of all-ceramic crowns and the connector area of fixed partial dentures: The influence of interfacial surface roughness[J]. J Dent, 2005,33(5) :405 -412.
  • 9Fleming GJ, Dickens M, Thomas L,I, et al. The in vitro failure of all-ceramic crowns and the eonnector area of fixed partial dentures using bilayered ceramic specimens: The influence of core to dentin thickness ratio [ J ]. Dent Mater, 2006, 22(8): 771 -777.
  • 10Pask JA, Fulrath RM. Fundamentals of glass to metal bonding: VIII, Nature of wetting and adherence [ J ]. J Am Ceram Soc, 1962,45 ( 12 ) :592 - 596.

引证文献7

二级引证文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部