摘要
介绍在直流仪器检定工作中,对于一些超差的仪表,采用调整、修理的方法,及时有效解决实际问题,使之满足生产的需要。
In working for DC instrument calibration, the methods of adjustment and repair were adopted to some meters with tolerance, which could solve the practical problem timely and effectively to meet production requirement.
出处
《贵州电力技术》
2014年第5期72-73,81,共3页
Guizhou Electric Power Technology
关键词
直流仪器
误差
绝缘电阻
零位电阻
稳定性
DC instrument
error
insulation resistance
zero-point resistance