摘要
目的了解新生儿ABO正反定型符合率,研究提高新生儿血型测定准确性的方法。方法用传统试管法检测当地新生儿ABO血型,以微柱凝胶卡和改良试管法、增强剂法及常规试管法、纸片法、微板法、聚凝胺法等7种方法检测抗-A、抗-B、抗-D抗体的效价,并进行新生儿血型检测比较。结果新生儿ABO正反定型符合率为83%(913/1 100);检测15份抗-A、抗-B、抗-D抗体的效价,敏感性最高是改良试管法和增强剂法,最差的是纸片法,新生儿标本检测结果类似。结论 ABO正反定型应增加血浆(血清)量并延长孵育时间或选用增强剂,从而提高新生儿血型检测的准确性。
Objective To understand the neonatal ABO type positive and reverse typing consistent rate and to improve the accuracy of the methods of neonatal blood.Methods The traditional tube method was used to detect the local neonatal ABO blood.The method of micro gel cards,improved tube method,enhancer and traditional tube method,paper,microplate,polybrene method to detect anti A,anti B,anti D titer,and neonatal blood detection comparator.Results Neonatal ABO positive and negative stereo types compliance rate was 83% (913/1 100);Detecting 15 copies of anti A,B,D titer,the highest sensitivity was improved intensifier tube method and the worst is the method of paper.The method of neonatal specimens was with the similar results.Conclusion ABO positive and negative stereo types should be increased by plasma (serum)levels and extending the incubation time,or using the"enhancer"of this study,thereby improving the accuracy of the newborn blood testing.
出处
《国际检验医学杂志》
CAS
2014年第11期1474-1475,共2页
International Journal of Laboratory Medicine
基金
中山市医学科研基金资助项目(2013A020159)
关键词
新生儿
脐带血
ABO
血型
RH(D)血型
正反定型
newborns
umbilical cord blood
ABO blood type
Rh (D) blood type
positive and reverse typing