摘要 目的探讨Sofia Influenza A+B FIA检测系统在快速诊断A、B型流感病毒中的临床应用价值。方法获取临床168例流感患儿的鼻咽拭子样本,分别通过Sofia Influenza A+B FIA检测系统和胶体金免疫层析(GICA)法分别进行A、B型流感病毒检测,并通过逆转录聚合酶链反应(RT-PCR)进行验证。结果 Sofia Influenza A+B FIA检测系统的阳性检出率为17.86%(30/168),高于GICA法;同时,与RT-PCR相比,对A型流感病毒和B型流感病毒的灵敏度分别达到83.3%和71.4%,特异性均达到100.0%。结论 Sofia Influenza A+B FIA检测系统是一种灵敏度和特异性均较高,能够快速检测A、B型流感病毒的方法。 Objective To evaluate the clinical application value of Sofia Influenza A+B fIA in detecting flu virus A and flu virus B.Methods Flu virus A and flu virus B was detected in 168 samples of nasopharyneal secretions which collected from children with influenza infection by Sofia Influenza A+B FIA,GICA and RT-PCR methods.Results Sofia Influenza A+B FIA positive detection rate was 17.86%(30/168),higher than GICA method.Compared with RT-PCR,its sensitivity and specificity for flu virus A and flu virus B were 83.3%,100% and 71.4%,100% respectively.Conclusion Sofia Influenza A+B FIA is a rapid clinical application method with high sensitivity and specificity.
出处 《国际检验医学杂志》 CAS 2014年第11期1476-1477,1481,共3页 International Journal of Laboratory Medicine
关键词 流感病毒 快速诊断 免疫荧光分析 聚合酶链反应 influenza virus rapid diagnostics test fluorescent immunoassay analysis polymerase chain reaction
  • 相关文献

参考文献11

  • 1Leonardi GP, Mitrache I, Pigal A, et al. Public hospital-based laboratory experience during an outbreak of pandemic influenza A (HIN1) virus infections[J]. J Clin Mierobiol,2010,48(4):1189-1194.
  • 2Bakerman P, Balasuriya L, Fried O, et al. Direct fluorescent-anti-body testing followed by culture for diagnosis of 2009 H1N1 influenza A[J]. J Clin Microbiol,2011,49(10):3673-3674.
  • 3Gavin PJ ,Thomson Jr RB. Review of rapid diagnostic tests for influenza[J]. Clin App Immunol Rev,2004,4(3): 151-172.
  • 4Berg B, Newton D, LeBar W. Comparison of direct fluorescent an tibody staining and real-time reverse transcriptase PCR for the detection of novel 2009 influenza A (HIN1) in nasopharyngeal sam ples[J]. J Clin Virol,2011,52(1) : 65-66.
  • 5Hurt AC,Alexander R, Hibbert J, et al. Performance of six influenza rapid tests in detecting human influenza in clinical specimens [J]. J Clin Virol,2007,39(2):132-135.
  • 6Uyeki TM, Prasad R, Vukotich C, et al. Low sensitivity of rapid diagnostic test for influenza[J]. Clin Infect Dis, 2009,48 (9) : e89-e92.
  • 7Lee CK,Cho CH, Woo MK, et al. Evaluation of Sofia fluorescent imnmnoassay analyzer for influenza A/B virus[J]. J Clin Virol, 2012,55(3) :239-243.
  • 8Rath B,Tief F,Obermeier P, et al. Early detection of influenza A and B infection in infants and children using conventional and fluorescence-based rapid testing[J]. J Clin Virol, 2012,55 (4) : 329- 333.
  • 9Beck ET,Jurgens LA, Kehl SC, et al. Development of a rapid automated influenza A, influenza B, and respiratory syncytial virus A/B multiplex real-time RT PCR assay and its use during the 2009 H1N1 swine-origin influenza virus epidemic in Milwaukee, Wisconsin[J]. J Mol Diagn,2010,12(1) :74-81.
  • 10Bucher DJ, Mikhail A, Popple S, et al. Rapid detection of type A influenza viruses with monoclonal antibodies to the M protein (M1) by enzyme-linked immunosorbent assay and time-resolved fluoroimmunoassay [J]. J Clin Mierobiol, 1991, 29 ( 11 ) 2484- 2488.