期刊文献+

主动脉内球囊反搏术不良反应的观察和护理 被引量:14

下载PDF
导出
摘要 目的探讨主动脉内球囊反搏术(IABP)在临床应用中不良反应的观察要点和护理方法。方法回顾性分析26例接受IABP治疗的患者不良反应的情况。结果出现触发不良26例,球囊充放气时间不当5例,出血症状7例,血小板减少9例,导管位移1例,导管堵塞1例,情绪异常18例,其中有拔管倾向者6例;死亡3例,自动出院5例,痊愈18例。结论通过严密的观察和评估,可以及早发现和治疗并发症,减少不良反应的发生。
作者 江薇 郑叶平
出处 《护士进修杂志》 2014年第12期1112-1113,共2页 Journal of Nurses Training
关键词 主动脉球囊反搏术 不良反应 护理 IABP patients Adverse reactions Nursing
  • 相关文献

参考文献2

二级参考文献16

  • 1Sanborn TA, Sleeper LA, Bates ER. Impact of thrombolysis, intra-aortic balloon pump counterpulsation, and their combination in cardiogenie shock complicating acute myocardial infarction: a report from the SHOCK trial registry. ACC Current Journal Review, 2001, 10: 66-67.
  • 2Stone GW, Ohman EM, Miller MF, et al. Contemporary utilization and outcomes of intra-aortic balloon counterpulsation in acute myocardial infarction: the benchmark registry. J Am Coil Cardiol, 2003, 41 : 1940-1945.
  • 3Macas A, Bukauskas T, ukeviiene I, et al. Intra-aortic balloon counterpulsation in acute myocardial infarction complicated by cardiogenic shock. Medicina, 2011, 47: 212- 218.
  • 4Severi L, Vaccaro P, Covotta M, et al. Severe intra-aortic balloon pump complications: a single-center 12-year experience. J Cardiothorae Vase Anesth, 2012, 26 : 604-607.
  • 5Parissis H, Soo A, A1-Alao B. Intra aortic balloon pump: literature review of risk factors related to complications of the intraaortic balloon pump Intra-aortic balloon pump use and outcomes with current therapies. J Cardiothorac Surg, 2011, 6: 147-152.
  • 6Vales L,Kanei Y, Ephrem G, et al. lntra-aortic balloon pump use and outcomes with current therapies. J Invasive Cardiol, 2011, 23: 116-119.
  • 7Alvarez JM, Gates R, Rowe D, et al. Complications from intra- aortic balloon counterpulsation: a review of 303 cardiac surgical patients. Eur J Cardiothorac Surg, 1992, 6: 530-535.
  • 8Kumbasar St), Ender S, Oktay S, et al. Mechanical complications of intra-aortic balloon counterpulsation. Int J Cardiol, 1999, 70: 69-73.
  • 9Gottlieb SO, Brinker JA, Borkon AM, et al. Identification of patients at high risk for complications of intraaortic balloon counterpulsation: a multivariate risk factor analysis. Am J Cardiol, 1984, 53: 1135-1139.
  • 10Goldberg M J, Rubenfire M, Kantrowitz A, et al. Intraaortic balloon pump insertion : a randomized study comparing percutaneous and surgical techniques. J Am Coil Cardiol, 1987, 9: 515-523.

共引文献14

同被引文献76

引证文献14

二级引证文献49

相关作者