期刊文献+

K3机用镍钛锉与K锉的临床应用比较

Comparison of Clinical Application between K3 Rotary Nickel-titanium Files and K Files
下载PDF
导出
摘要 目的:比较K3机用镍钛锉与手用K型锉的临床应用。方法:选择285颗患牙(失查数5颗),共526个根管,随机数字表法分为K3组和K锉组,分别用K3机用镍钛锉和K锉进行根管预备,比较两组患者根管预备时间、根管预备术后疼痛反应和根管充填质量。结果:K3组所用时间明显少于K锉组;K3组根管预备后疼痛发生率为(5.51%),较K锉组的根管预备后疼痛发生率(10.24%)明显降低(P<0.01);K3组根管恰填率为(94.18%),较K锉组(86.22%)明显提高(P<0.01)。结论:K3机用镍钛锉预备根管具有效率高、成形能力强、根充效果好、明显减少术后疼痛等优点,是一种理想的根管预备器械,值得临床上广泛应用。 Objective:To make a comparison between K3 rotary nickel-titanium files and hand operated K files. Method:285 bad teeth(5 missing),totally with 526 incisive canals were divided into K3 group and K file group randomly,for which root canal preparations were made respectively with rotary nickel-titanium files and K files,to compare the time of root canal preparation,pain reaction after the preparation and filling quality of root canal within each group. Result:The result proved that the root canal preparation time using rotary nickel-titanium files of the K3 group was much less than that of the K file group. The rate of pain reaction after K3 preparation was 5.51%,which was less than that of K file group(10.24%)(P〈0.05),and the well-filled rate of K3 group was 94.18%,which was more than that of the K file group(86.22%)(P〈0.05). Conclusion:Rotary nickel-titanium files have high efficiency,strong shaping ability, good root filling effect,which can significantly reduce postoperative pain,ideal root canal preparation equipment,worthy of clinical application.
作者 杜美仪
出处 《中国医学创新》 CAS 2014年第16期44-46,共3页 Medical Innovation of China
关键词 K3镍钛锉 根管预备 不锈钢K锉 疼痛 根管治疗术 K3 rotary nickel-titanium files Root canal preparation Stainless steel K file Pain Root canal trerapy
  • 相关文献

参考文献12

二级参考文献72

  • 1刘沛,凌均棨,高燕.机用镍钛器械预备清理根管效果的定量分析[J].牙体牙髓牙周病学杂志,2004,14(3):158-161. 被引量:12
  • 2胡晓莉,凌均棨,陈罕,谷海晶.两种镍钛机动器械预备根管的效果分析[J].中华口腔医学杂志,2005,40(1):30-33. 被引量:33
  • 3陈君,岳林,王嘉德,高学军.根管扩大程度与牙根强度和应力分布的关系[J].中华口腔医学杂志,2006,41(11):661-663. 被引量:42
  • 4葛久禹.根管治疗学[M].2版.南京:江苏科技出版社,2007:114,.
  • 5Sarkar NK, Redmond W, Schwaninger B, et al. The chloride corrosion of four orthodontic wires [ JJ. Journal of Oral Rehabilitation, 1983,10 : 121-128.
  • 6Berutti E,Angelini E, Rigolone M, et al. Influence of sodium hypochlorite on fracture properties and corrosion of PmTaper Rotary instruments[ J]. Int Endod J,2006,39(9) :693 -699.
  • 7Angelini E, Zucchi F, Caputo A. Degradation processes on metallic surfaces. In : Barbucci R, ed. Integrated Biomaterial Science,2002 : 308-323.
  • 8Yared GM, Bou Dagher FE, Machtou P. Failure of profile instruments used with high and low torque motors [ JT. Int Endod J,2001,34 : 471-475.
  • 9Inan U, Aydin C, Tunca YM. Cyclic fatigue of protaper rotary nickel-titanium instruments in artificial canals with 2 different radii of curvature [ J ]. Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics ,2007,104 (6) : 837-840.
  • 10Gambarini G. Rationale for the use of low-torque endodontic motors in root canal instrumentation [ J ]. Endodontics and Dental Traumatology,2000,16:95-100.

共引文献116

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部