高频电刀质量控制检测是军队医院质控工作的重要组成部分。在按照军队卫生装备质量检测技术规范对高频电刀进行质量控制的实际检测工作中,尤其是对输出功率、高频漏电流和中性电极安全管理(REM)进行检测时存在很多疑难点,严重影响了质控工作的顺利开展。本文通过对疑难点进行分析,帮助广大质控工作者更好的理解军队卫生装备质量检测技术规范,科学有效地开展质控工作。
Quality control test of high frequency electrotome is an important part of medical equipment quality control in military hospitals. There are many difficult points in quality control test of high-frequency electrotome according to the military medical equipment technical speciifcations, especially in the management of output power, high-frequency leakage current and resistance emergency management. This paper analyzes these dififcult points, in order to help quality control engineers better understand the technical speciifcations and effectively carry out quality control.
出处
《中国医疗设备》
2014年第6期88-90,共3页
China Medical Devices
关键词
高频电刀
质量控制
功率
高频漏电流
REM
high frequency electrotome
quality control
power
high frequency leakage current
resistance emergency management