摘要
分析了高层建筑中设置消防电梯的必要性以及高层建筑设计防火规范中有关消防电梯设置要求的不明确地方。以某文化艺术中心为例,就其文化艺术中心的博物馆和城市规划展览馆的消防电梯设置进行介绍,并从经济实用安全的角度进行分析,讨论该文化艺术中心博物馆和规划展览馆地下和顶层不设置消防电梯和减少消防电梯设置数量的可行性。
The necessary of setting fire elevator in high-rise building,and the uncertainty of requirement for high-rise building fire elevator in high-rise building fire design standard was analyzed.Taking a cultural arts center as an example,the fire elevator setting in museum and urban planning exhibition hall were introduced.In points of economic,practicality and safety,the feasibility of skipping fire elevator at the top and underground of the museum and urban planning exhibition hall,or reducing the elevator number were discussed.
出处
《消防科学与技术》
CAS
北大核心
2014年第6期660-662,共3页
Fire Science and Technology
关键词
消防电梯
疏散楼梯
火灾危险性
fire elevator
evacuation elevator
fire hazard