期刊文献+

自制高分子微泡超声造影机械指数与频率和峰值强度的相关性 被引量:6

Correlation between mechanical index and frequency with peak intensity in contrast-enhanced ultrasound with self-made polymer acoustic contrast agents
下载PDF
导出
摘要 目的探讨兔体内自制高分子微泡CEUS机械指数和频率与峰值强度的相关性。方法采用单乳化法制备包裹全氟戊烷的嵌段共聚物微泡造影剂,固定其他超声扫描条件,对6只新西兰大白兔于机械指数0.04、0.09、0.17、0.34和超声频率3.5、5.0、6.5、8.0MHz下进行肾脏CEUS,分析机械指数和频率与峰值强度的相关性;静脉注射10倍造影剂量微泡,观察毒性反应。结果自制微泡平均粒径为(3.92±1.43)μm。兔体内峰值强度与机械指数呈正相关(r=0.99,P<0.05),与超声频率呈负相关(r=-0.93,P<0.05);静脉注射大剂量微泡后,未见明显毒性反应。结论采用自制高分子微泡作为造影剂对兔进行CEUS时,峰值强度与机械指数呈正相关,与超声频率呈负相关;微泡安全性良好。 Objective To explore correlation between mechanical index and frequency with peak intensity in CEUS of rabbit kidney with self-made polymer microbubbles as contrast agents. Methods The diblock copolymer microbubbles encapsulating perfluoropentane were prepared with single emulsification method. CEUS was performed with mechanical index of 0.04, 0.09, 0. 17, 0.34 and frequency of 3.5, 5.0, 6.5, 8.0 MHz, respectively, with the other condition being unchanged. The correlation between mechanical index and frequency with peak intensity were analyzed. The toxicity reactions of the animals were observed after intravenous injection of microbubbles of ten-fold dose for CEUS. Results The mean diameter of the sell-made microbubbles was (3.92± 1.43)μm. The peak intensity was positively correlated with peak intensity (r=0.99, P〈0.05) and negatively correlated with ultrasonic frequency (r=-0.93, P〈0.05). After intravenous injection of large dose microbubbles, no obvious toxicity reaction was found in all the animals. Conclusion The peak intensity has positive correlation with mechanical index and negative correlation with frequency in CEUS of rabbit kidney using self-made polymer acoustic contrast agents that have great safety.
出处 《中国医学影像技术》 CSCD 北大核心 2014年第6期805-808,共4页 Chinese Journal of Medical Imaging Technology
基金 全国大学生创新创业训练计划项目(201310392022)
关键词 超声检查 造影剂 机械指数 超声频率 Ultrasonography Contrast media Mechanical index Ultrasonic frequency
  • 相关文献

参考文献10

  • 1Tlaxca JL, Rychak J J, Ernst PB, et al. Ultrasound-based molec- ular imaging and specific gene delivery to meseBteric vaseulature by endothelial adhesion molecule targeted microbubbles in a mouse model of Crohn's disease. J Control Release, 2013, 165 (3) :216-225.
  • 2Ren ST, Liao YR, Kang XN, et al. The antitumor effect of a new doeetaxel loaded microbubble combined with low-frequency ultrasound in vitro: Preparation and parameter analysis. Pharm Res, 2013,30(6) :1574-1585.
  • 3Wang YH, Liao AH, Chen JH, et al. Photoacoustic/ultrasound dual-modality contrast agent and its application to thermotherapy. J Biomed Opt, 2012,17(4):045001.
  • 4Browning RJ, Mulvana H, Tang MX, et al. Effect of albumin and dextrose concentration on ultrasound and microbubble media-ted gene transfection in vivo. Ultrasound Med Biol, 2012,38(6): 1067- 1077.
  • 5万鲲,高申,费翔,张顺欣.高分子聚合物PLGE超声微泡的制备与体外显影研究[J].中国药物应用与监测,2010,7(6):335-337. 被引量:2
  • 6张群霞,骆杰,冉海涛,王志刚,郑元义,张辉,钟世根,李巧.比较脂质微泡与聚合物超声造影剂的微循环流变学[J].中国医学影像技术,2011,27(8):1525-1527. 被引量:6
  • 7赵玉英,智光,徐勇,崔文瑾,王身国,何振山.新型聚内酯超声造影剂的体外基本特性研究[J].中华超声影像学杂志,2006,15(5):381-383. 被引量:5
  • 8Correas JM, Quay SD. EchoGen emulsion: A new ultrasound contrast agent based on phase shift colloids. Clin Radiol 1996,51 (Suppl 1) : 11-14.
  • 9Albrecht T, Cosgrove DO, Correas JM, et al. Renal, hepatic, and cardiac enhancement on Doppler and gray-scale sonograms obtained with EchoGen. Acad Radiol, 1996, 3 (Suppl 2) : 198- 200.
  • 10陈琬萍,黄丹凤,陈志奎,林礼务,薛恩生,黄嵘森,林鹏.嵌段共聚物超声微泡造影剂的制备及体内外显影研究[J].中国超声医学杂志,2014,30(3):273-276. 被引量:6

二级参考文献30

共引文献11

同被引文献43

引证文献6

二级引证文献17

相关作者